![Curtis 1212S Manual Download Page 24](http://html1.mh-extra.com/html/curtis/1212s/1212s_manual_2699552024.webp)
Curtis 1212S Manual,
Rev. B
21
MISCELLANEOUS MENU
ALLOWABLE
PARAMETER
RANGE
DESCRIPTION
Sequencing Delay
0 – 1000 ms Sets the delay time for the interlock switch debounce.
Sleep
0 – 60 minutes Sets the delay time between the last throttle request or serial communication and
when the controller goes into sleep mode. Setting the delay to zero disables the
sleep function.
Reset Drive Time
On , Off
The controller’s hourmeter logs the total drive time since the last reset; this
record is accessible through the Monitor menu.
Setting this parameter On zeroes the hourmeter and starts a new log; this is
typically done when the vehicle is serviced. Reset Drive Time is automatically set
to Off after the hourmeter is reset.
Emergency Stop
On , Off
Defines how the vehicle will respond when the emergency stop button is pressed.
On = The EM brake will be engaged rapidly when the emergency stop button
is pressed; the battery is disconnected and the vehicle will stop abruptly.
Off = When the emergency stop button is pressed, the battery is disconnected
and the vehicle will decelerate for a short distance before it fully stops.
Pump SRO
On , Off
Pin J1-9 can be used to check the status of lift/lower switches that are wired to
KSI; if these switches are closed before KSI is turned on, the controller will issue
a Pump SRO Fault. Wiring is shown in Figure 7.
To enable this feature, set the Pump SRO parameter On.
The Lift Lockout Output is affected by both the External Lift Lockout
parameter (see BDI menu) and the Pump SRO parameter as follows.
Reset Parameter
On , Off
When programmed On, all program parameters are reset to their default values.
3 — PROGRAMMABLE PARAMETERS: Miscellaneous Parameters
Fig. 7
Wiring
for Pump SRO.
PARAMETER SETTINGS
LIFT LOCKOUT OUTPUT
PUMP SRO
EXTERNAL LIFT LOCKOUT
TRIGGERED BY
On
—
Pump SRO Fault
or Internal BDI
Off
On
Lift Lockout input from 906
Off
Internal BDI
1
2
3
4
5
6
7
8
9
10 11 12 13 14
(Pin 9)
KSI
PUMP CONTACTOR COIL
LIFT SWITCH
B–
LOWER VALVE COIL
LOWER SWITCH
V
RRM
≥
100 V,
IF
≥
1A
❉
❉
J1-3