danger of fire or explosion in an enclosed space, the enclosed volume fogging time and required
formulation volume should be carefully calculated.
5.
Proper and Improper Use.
The following rules apply to the operation of this machine:
Read the entire manual before operating the machine and pay particular attention to all
CAUTIONS AND WARNINGS.
Store formulation in its original labeled container.
Use an extension cord which is properly rated for voltage, current, and length and which is free
from nicks, cracks, and other signs of prior abuse. For lengths up to 100 feet, (30.5 meters)
cords with No. 12 AWG wire are usually adequate.
Replace damaged or worn electric cord immediately.
Turn the flow valve CLOCKWISE to the OFF position after each spray application while the motor
is still operating to allow clearing of the lines. This will also prevent a siphon effect if the unit is
ever accidentally knocked over with the valve remaining open.
Always comply with any requirements for protective clothing, goggles, gloves, facial masks, or
respirator required by the formulation label.
Ensure that formulation is applied only in strict compliance with the formulation label as well as
local, state, and federal regulations.
Do not
spray flammable liquids near open flame or other source of ignition.
Do not
use a machine that is broken or damaged in any way.
Do not
alter the machine by adding or removing parts.
Do not
restrict the motor blower inlet area.
Do not
tamper with the output nozzle.
Do not
allow the machine to operate unattended.
Do not
apply more than one gallon of formulation per 50,000 cubic feet (2.7 liters per 1,000 cubic
meters enclosed space). Exceeding this concentration is both hazardous and wasteful.
DO
DO NOT
Curtis Dyna-Fog, Ltd. 2008