background image

Technical Details of Dyna-Fog 6 V DC Sealed Lead Acid Batteries  

Sealed Construction

 - SLA batteries unique construction and sealing technique guarantee 

that no electrolyte leakage can occur from the terminals or case of any battery. This feature 
insures safe, efficient operation of SLA battery in any position.  

Electrolyte Suspension System

 - All SLA batteries utilize an electrolyte suspension system 

consisting of a glass fiber separator material. This suspension system allows maximum life 
and service.  

Gas Generation

 - Batteries have a unique design that effectively controls generation of gas 

and allows recombination within the battery over 99% of gas generated during normal usage.  

Maintenance Free Operation

 - During the expected five years float service life of SLA 

batteries, there is no need to check the specific gravity of the electrolyte, or add water. In 
fact, there is no provision for these maintenance functions.  

Low Pressure Venting System

 - SLA batteries are equipped with a safe, low pressure 

venting system, which operates at 7 psi to 10 psi, designed to release excess gas and reseal 
automatically in the event that gas pressure rises to a level above the normal rate.  

Cyclic Service Life

 - Depending upon the average depth of discharge, over 1,000 

discharge/ recharge cycles can be expected from batteries  

Low Self Discharge

 - At room temperature, its self-discharge rate of SLA batteries is 

approximately 3% of rated capacity per month.  

Operating Temperature Range

 - SLA batteries may be used over a broad range of ambient 

temperatures.  

Optional Sealed Lead Acid Battery Available

 – Allows  extended operation where traps 

cannot be maintained on a daily basis. Contact Curtis Dyna-Fog for more information. 

Dyna-Fog offers an optional power source that can be used, a rechargeable 6 
volt 12 Amp-Hour battery, which allows longer operation time of the Light trap 
between charging periods. 
Be sure to observe that the battery is installed and connected with the proper 
polarity to assure proper operation and prevent damage to the trap. 

 

 

 

 

 

 

 

- Page 7- 

CAUTION 
As DC current is 
unidirectional, wire 
leads are coded: the 
ribbed wire goes to the 
(+) and the smooth wire
goes to the (-) polarity. 
The plastic housing of 
the connectors are also 
coded, the tab goes to 
the (+) polarity. 
Orienting the wires in 
the wrong direction will 
prevent the unit from 
operating properly. 

COLOR FOR

FOR NEGATIVE SIDE

AREA IN RED

POSITIVE SIDE

COLOR FOR

POSITIVE SIDE

SYMBOL (+) FOR

NEGATIVE SIDE

BLACK SLEEVE

NEGATIVE SIDE

SYMBOL (-) FOR

IDENTIFY

TAB TO

POSITIVE SIDE

RIBBED WIRE FOR
POSITIVE SIDE

ASSEMBLY

BATTERY

OPTIONAL

AREA IN BLACK

Summary of Contents for 2505

Page 1: ......

Page 2: ...of the Light Trap 5 Operating the Light Trap 5 Battery Holder 6 Recommended Light Bulb 6 Troubleshooting Tips 7 Optional Sealed Lead Acid Battery 7 Exploded Isometric Parts diagram 8 Parts List 9 Optional Air Gate 10 Optional CO2 Gas kit 10 Optional CO2 Dry Ice kit 10 Other Light Traps 10 Page 2 ...

Page 3: ...dex of the number of mosquitoes in an area This light trap was designed to be an efficient means for collecting samples of adult mosquitoes Once collected the mosquitoes can then be identified and counted to provide a statistical representation of the population density and type of species in any given area Collecting a sample of mosquitoes using this light trap can provide invaluable information ...

Page 4: ......

Page 5: ...t of mosquitoes collected NOTE FOLLOW THE SPECIFIC INSTRUCTION FROM THE SCIENTIFIC TECHNICAL PERSONNEL IN YOUR VECTOR CONTROL PROGRAM AND OR MOSQUITO CONTROL DISTRICT Operating the Light Trap NOTE To yield the most accurate results the trap should be operated for five consecutive nights When connected the light trap to a 6 volt DC power source the trap will begin operating fan and light Both fan a...

Page 6: ...tors are also coded side of the tab goes to the polarity Recommended Light Bulb types are Bulb Type Voltage Current MSCP 503 5 1 Volts 150 ma 6 47 6 3 Volts 150 ma 5 44 6 3 Volts 250 ma 9 MSCP Mean Spherical Candlepower Higher MSCP means brighter light The Light Trap model 2505 is supplied with the Light Bulb 44 Troubleshooting Tips Problem Possible Cause Corrective Action Unit will not operate Ba...

Page 7: ...e Life Depending upon the average depth of discharge over 1 000 discharge recharge cycles can be expected from batteries Low Self Discharge At room temperature its self discharge rate of SLA batteries is approximately 3 of rated capacity per month Operating Temperature Range SLA batteries may be used over a broad range of ambient temperatures Optional Sealed Lead Acid Battery Available Allows exte...

Page 8: ......

Page 9: ......

Page 10: ...ng gates promotes battery conservation and allows longer time periods of unattended and uncollected light trap specimens without specimen escape CURTIS DYNA FOG self closing gate can be used on any light trap including the competitors After installing self closing gate for trap with electronic switch you can set the function switch to position number 3 for battery conservation PARTIAL OPEN GATES A...

Page 11: ...______________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ____...

Page 12: ...e control of boom functions rotation of turntable and angle of nozzles Diversity of pumping systems Gear Piston and Diaphragm Pressurized system available for overseas market Optional Radar Syncroflow 40 cc Two cycle portable machines also available DYNA FOG Offers a complete and wide assortment of aerosol generator systems CURTIS DYNA FOG Ltd www dynafog com Call or write today for a free brochur...

Reviews: