Installation
Preparing the Worktop
Cut out the work surface following the dimensions shown in the drawing below.
For the purpose of installation and use, a minimum distance of 5cm space must be left around the cut out.
Be sure the thickness of the work surface is at least 20mm. Use a heat-resistant work surface material to avoid
deformation caused by the heat from the hob. The minimum distance between the hob and the cupboard should
be at least 65cm.
Ensuring Adequate Ventilation
Always make sure the ceramic cooker hob is well ventilated and that the air inlet and outlet are not blocked.
This hob requires an adequate supply of fresh, cool air to fully function. The base of the hob must have direct
unrestricted ventilation to the room where the hob is installed. Follow the requirements below.
5mm
10cm
2 cm (min)
600
485
50
560
40
40
(min)
(min)
580
510
45
65 cm (min)
There are ventilation holes around the outside of the hob.
YOU MUST
ensure that these holes are not
blocked by the worktop, when you put the hob into position.