NOTE: Make all electrical connections in accordance with 

the National Electrical Code and any applicable local code 

requirements including grounding.

NOTE: Verify supply voltage matches rating before wiring.

•  Verify service leads meet nameplate temperature rating.

•  Units are provided with leads exiting the fixture for  

  connection with service leads and (if ordered) wired  

  dimming. 

Wired Dimming

•  Connect wired dimming leads per Table 1

•  Customer supplied dimming leads 600 volt min.
TABLE 1. Wired Dimming Control Connections
 

0 VDC (-) 

Gray Lead

 

Up to 10 VDC (+) 

Violet Lead

2d. Recessed Mount (Figure 4): 

•   Cut 15” x 15” square opening in underside of canopy.

•  Install accessory mounting plate to front face of fixture  

  with four # 10 screws provided.

•  Remove cover plate knockout plugs (1/2” or 3/4”) for  

  desired conduit diameter.

•  Feed flex conduit through canopy opening and secure  

  to cover plate.

•  Connect fixture leads to service leads from flex conduit  

  in accordance with Section 3 “Wiring.”

•  Secure cover plate to back of fixture with four #10 screws  

  provided

•  Secure accessory mounting plate to underside of canopy  

  using four #10 toggle bolts (not provided). 

2e. Surface Mount Conduit Entry (Figure 5): 

•   Secure fixture to underside of canopy with four #10  

  toggle bolts (not provided).

•  Remove fixture cover plate.

•  Remove side conduit plug and replace with customer  

  supplied conduit on desired side.

•  Feed customer supplied electrical wires through conduit  

  into fixture electrical cavity.

  with Section 3 “Wiring.” 

•  Re-install fixture cover plate

2f. Surface Mount w/ Beauty Plate (Figure 6):   

•   Remove cover plate knockout (1/2” or 3/4”) for desired  

  conduit diameter.

•  Feed flex conduit through canopy opening and secure  

  to cover plate.

•  Connect fixture leads to service leads from flex conduit   

  in accordance with Section 3 “Wiring.”

•  Secure cover plate to top of fixture with four #10 screws  

  provided.

•  Secure beauty plate to underside of canopy with four  

  #10 toggle bolts (not provided).

•  Install fixture to beauty plate with four #10 self-drilling  

  screws provided.

15 in. x 15 in.

CUTOUT

COVER

PLATE

MOUNTING

PLATE

#10 TOGGLE BOLTS

NOT PROVIDED

#10 SCREWS

Provided

#8 SCREWS

Provided

#10 TOGGLE BOLTS

NOT PROVIDED

CONDUIT PLUGS

Fixture

Cover Plate

#10 TOGGLE BOLTS

NOT PROVIDED

#10 SELF DRILLING 

SCREWS PROVIDED

#10  SCREWS

PROVIDED

BEAUTY PLATE

PROVIDED

COVER PLATE

PROVIDED

Figure 4

Figure 5

Figure 6

Wiring

3

Summary of Contents for Evolve ECLS Series

Page 1: ...t has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful inter...

Page 2: ...Mounting Figure 3 Feed service wires through conduit mounting plate and thread plate onto rigid conduit Tighten set screw into conduit to lock For 347 volt units install tether with 10 screws include...

Page 3: ...rside of canopy using four 10 toggle bolts not provided 2e Surface Mount Conduit Entry Figure 5 Secure fixture to underside of canopy with four 10 toggle bolts not provided Remove fixture cover plate...

Page 4: ...ea or covered with a secured tarp to keep water off the corrugated cardboard packaging RISK OF ELECTRICAL SHOCK Make certain power is off before attempting any maintenance of the product WARNING Maint...

Page 5: ...imites sont tablies pour assurer une protection raisonnable contre les interf rences nuisibles lorsque l quipement est mis en service dans un environnement commercial Cet quipement met utilise et peut...

Page 6: ...s No 10 comprises au trou dans la plaque de montage du conduit et dans le corps les appareils en 120 277 volts ne demandent pas de rallonge mais la vis No 10 doit tre install e dans le trou de la plaq...

Page 7: ...No 10 non fournis Enlevez le bouchon du conduit lat ral et remplacez le par un conduit fournis par le client du c t voulu suivant la Section 3 C blage 2f Montage en surface avec plaque d corative Fig...

Page 8: ...en carton ondul bo te en carton Stockez les appareils emball s dans un endroit sec et couvert ne d passant pas 40 C 40 F 50 C 122 F tel qu un magasin sous toit ou couvert d une b che pour viter l eau...

Page 9: ...t n dise ados para proporcionar protecci n razonable contra interferencias perjudiciales al operar el equipo en un entorno comercial Este equipo genera utiliza y puede irradiar energ a de radiofrecuen...

Page 10: ...voltios instale la atadura con dispositivo al agujero de la placa de montaje del conducto y la cubierta unidades de 120 277 no requieren una en el agujero de la placa de montaje del conducto Conecte l...

Page 11: ...ale de nuevo la placa de cubierta del dispositivo Figura 6 Quite el prepunzonado de la placa de cubierta 1 27 cm o 1 91 cm 0 5 o 0 75 pulgadas para el di metro deseado suj telo a la placa de la cubier...

Page 12: ...a operaci n o el mantenimiento Debe ser deseada m s informaci n o se sugieran problemas particulares que no est n cubiertos para los prop sitos del comprador el asunto debe remitirse a GE Current a Da...

Reviews: