Troubleshooting Guide

Problem

Possible Issue

Items to check

Orbit Marine IC display
reads “ERR” 

Pump is clogged or impeller  
requires cleaning

Wrong power supply plugged in

Power supply has failed

Pump does not turn on

Remove pump from service and clean

(http://current-usa.com/how-to-clean-wave-pumps/)

Ensure power supply(PS) green indicator 
light is ON

(If green light is off, power supply needs replaced)

Ensure power supply is plugged into AC
GFCI outlet that has been reset

Ensure correct voltage (24VDC only) and 
wattage power supply is being used

(#6009=6w, #6010=18w, #6011=36w)

GFCI has tripped

LED display is plugged into the
wrong microUSB port

Ensure ONLY 24VDC power supply is plugged
into wave pump, 12VDC for LED lighting

Pump appears to spin
backwards**

**NOTE: DC pumps cannot
spin backwards but when 
unbalanced, water is 
displaced out the sides of 
pump.

Pump impeller is unbalanced

Ensure nothing blocks water flow (including 
rocks or a hand.) Turn pump off and remove 
from water. Disassemble and re-assemble to 
re-balance impeller shaft. 

Wave pump not reacting
to Orbit Marine IC remote

LOCK Button is activated or
IR remote battery needs replaced

LED display works but
pump does not turn ON

Press the LOCK/UNLOCK key on Orbit Marine
IC remote to unlock programming, replace
IR remote battery.

how-to

+

troubleshoot eFlux wave pumps

Ensure wave pump LED is ONLY plugged into
microUSB Port #2 (second from right)

Wave Pump Kit LED 
display does not
turn on or is partially
illuminated

Incorrect power supply being
used

Pump powers up
intermittantly

HUB connection plug is loose or
possibly damaged

Ensure plugs are all connected correctly. If
connector on HUB is loose, please contact
support to receive a replacement HUB.

Impeller and shaft not clean

https://current-usa.com/warranty-support/

Remove pump from service and clean shaft
and inside impeller

(http://current-usa.com/how-to-clean-wave-pumps/)

Wave pump Kit not 
responding to IR remote

Remote IR sensor disconnected

Remote IR sensor disconnected

IR remote battery needs replaced

Check and replace IR remote battery

Note: To reset pump and HUB, disconnect all cables & power and re-connect