Current Cost EnviR User Manual Download Page 8

8

EnviR - The SmartR Monitor

•  Check the display to ensure that it is reading the signal and that watts are being displayed. 
• Re-attach the protective cover and close the panel.
• Turn On the Main Breaker.

setting the clock

• Press the OK button for three seconds.
• The screen will clear and clock hours will flash.
• Use the UP ( ) or DOWN (V) buttons to adjust the hour.
• Once the correct hour is selected press OK button.
•  The minutes will now flash. Use the UP ( ) or DOWN (V) buttons to adjust 

the minutes. Once the correct minute has been selected press the OK button.

setting the base Rate

The unit has been programmed with a default rate of $0.1396 cents per kWh. To find out your  
local rate, contact your local utility or review your last utility bill and divide the total bill amount / 
KWhs used. To adjust your rate:

• Push the UP ( ) button and hold for three seconds.
• Press OK. The display will flash normal price.
• Press UP ( ) or DOWN (V) buttons to adjust price on first 2 digits. 
• Press OK. The display will flash last 2 digits.
• Press UP ( ) or DOWN (V) buttons to adjust price on last 2 digits.
• Press OK.

multiple Rate Tariffs

The EnviR can be programmed to calculate different KWh unit rates for electricity consumed at different 
times of day. In order to program different rates:
•  Press and hold the UP ( ) and DOWN (V) buttons together until the LED flashes. Then release both 

buttons.

•  Using the UP ( ) and DOWN (V) buttons you can select your low cost rate. Press the OK button to 

confirm rate.—If you do not select a different rate, then you will not see the time section.

•  You will see the clock flashing. Using the UP ( ) and DOWN (V) buttons you can now set the time that 

your low rate starts. Press the OK button to confirm.

•  Using the UP ( ) and DOWN (V) buttons you can set the time your normal rate starts. 

Press the OK button to confirm.

• The display will resume normal operation.

Time

Last       Days

Yesterday

kWh

Night

Per
Day

Day Eve

Appliance

Time

30

kW

Energy Now
Cost

$

PowerSave Envi R Man.indd   8

04/08/2011   10:27

Summary of Contents for EnviR

Page 1: ...1 Monitor User Guide The SmartR Monitor PowerSave Envi R Man indd 1 04 08 2011 10 27 ...

Page 2: ...ent 6 Sensable software Pairing additional C enabled displays to the transmitter 6 Install Transmitter and CT Clamps 7 Setting the Clock 8 Setting the Base Rate 8 Multiple Rate Tariffs 8 Advanced Features 9 Full System Reset 9 DATA output 9 Troubleshooting 10 Safety and care of your monitor 10 Limited One Year Warranty 11 Specifications 11 Contact Us 12 PowerSave Envi R Man indd 2 04 08 2011 10 27...

Page 3: ...ied electric meters The EnviR is an informational tool only Utility electric meters monitor usage full time and are therefore more accurate We recommend that you install the display in your kitchen or other area where you can check the display regularly Over time you will learn more about your energy use pattern and will know when it is higher than normal As you leave your home or go to bed a quic...

Page 4: ... Test it by turning a light on or off and watch the number change Shows how much money you are spending per day and per month based on the energy being used and the cost rate in effect Indicates number of CT clamps connected Accumulated energy usage over the past day week and month Mode changes every 10 seconds or can be scrolled using the OK button Shows cost change based on a recent change in en...

Page 5: ...then a wireless connection is made and the system is paired If the display looks like the image on the left then it needs to be paired Proceed to pairing instructions below System is Paired Pairing Needed Pairing the EnviR Display and Transmitter Place the transmitter and the display in the same room Using the tip of a pen press the small button found in the front center of the black transmitter a...

Page 6: ...cessful Please note that the voltage shown on the display is used for the EnviRs internal calculations this has nothing to do with the display power adaptor Sensable software Pairing additional C2 enabled displays to the transmitter The new Sensable software found in the EnviR transmitter allows you to set up additional C2 enabled displays within the home To pair additional displays please underta...

Page 7: ...e so that the protective cover can be remounted If there is not enough room seek installation help from a qualified electrician Place the transmitter as high in the enclosure as possible A Velcro sticker is used to secure the transmitter in place Locate the two main incoming cables coming from the meter and feeding the main breakers in the panel They are usually the 2 thickest cables and are norma...

Page 8: ...rmal price Press UP or DOWN V buttons to adjust price on first 2 digits Press OK The display will flash last 2 digits Press UP or DOWN V buttons to adjust price on last 2 digits Press OK Multiple Rate Tariffs The EnviR can be programmed to calculate different KWh unit rates for electricity consumed at different times of day In order to program different rates Press and hold the UP and DOWN V butto...

Page 9: ... display Press and hold the UP and DOWN V buttons as you push the display power lead into the back of the display When RED LED light flashes release the buttons The display will show software version number Remove and reconnect the power lead on the display This switch on wipes all history and pairing ID s and burn in fresh defaults Display unit will need to be paired again and rates need to be re...

Page 10: ...Do not open the equipment or touch any of its electronic circuitry Do not hit strike or drop the equipment if the display gets broken take special care not to touch the liquid crystals Do not use this product for any other purpose for which it was intended Changes or modifications not expressly approved by the party responsible for Compliance could void the User s authority to operate the equipmen...

Page 11: ... meter Specifications Product Size 14cm x 17cm base x 10 5 cm Viewable Screen 7 3cm x 9cm Retail Package Size 38 5cm x 18 5cm x 7cm Internal Power Requirement Mains block adapter nominal 1 0 watt Display power supply UL listed Physical Format Table top Energy Monitored Electricity gas LPG oil in development Receiver 433MHz SRD band Communication Platform C architecture Sensor Coding Recognition 10...

Page 12: ...mmunications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase t...

Reviews: