Ed. 0121 - 70702722 REV.04 Michelangelo hood - Use and maintenance
9
Ø150mm
[Ø5.9 in. ]
D
C
Fig.9.
Fig.10.
Fig.11.
A
2
B
1
Replacing components
The user must replace
only
the stated components: in
case of a fault or for extraordinary maintenance, contact
the Dealer requesting service from an authorised
technician. As replacements, always use original spare parts to
be requested from the Dealer: using non original parts might
cause injuries to people, non optimal performance and even
serious damage of the appliance itself.
Before any replacement, it is necessary to
switch off
the power
to the appliance (acting on the system
switch) and wear suitable personal protection
equipment (e.g. gloves, etc.).
Any component should be replaced with the
hood and underlying oven completely cold and
wearing adequate personal protection devices
(e.g. gloves, etc.).
Suction/exhaust pipe replacement
Fig.9. Suction pipe
The pipe
A
and fitting
B
should be ordered from the Dealer
as spare parts. Using other types of pipes voids the warranty.
Fig.10. Flue
The flue
D
is not supplied by the Manufacturer as a spare part
and thus must be purchased at a specialised service centre.
The flue
D
must:
•
be exclusively used by the equipment,
•
have a
150 mm [Ø5.91 in.]
diameter (to guarantee
correct draught up to a maximum of 20 linear metres [787.4
in.], three curves and a terminal on the roof ),
•
be made of high temperature resistant stainless steel,
•
meet current regulations.
Filter and filter handle replacement
Fig.11.