5. Installation
36
PNEG-499
Cycle Plus Pan Feeder
Cable and Winch Installation (Continued)
For systems longer than 360' (109.73 m), install the cable with double reduction pulleys.
The distance between the winch drum and the double reduction pulley should be slightly greater than the
distance the feed line is to be raised.
Tighten the set screw on the winch drum to anchor the cable.
Turn the winch drum one full revolution. Guide the cable against the flange at the bottom of the
winch drum.
NOTE:
The cable must not wrap over itself on the drum, but should lay as closely as possible to each
previous wrap.
Figure 5AJ
Drop Cable Installation
Attach the 1-3/4" (4.445 cm) pulley to each hook. Place the hangers to the feed line directly below each
pulley. Spread the wire hanger just enough to force it over the auger tube.
To each pulley, thread the 1/8" drop cable through and attach to the 3/16" winch cable about 6" (15 cm)
from the pulley towards the drum with the 1/8" x 3/16" cable clamp sleeves.
NOTE:
Be sure the hangers are not touching the shocker wire.
Figure 5AK
Ref #
Description
J
Distance to be Raised
K
3-1/2" Cast Pulley
Ref #
Description
A
Hook
B
Cable Clamp Sleeve
C
1-3/4" Pulley
D
Winch Cable
E
Drop Cable
Summary of Contents for PNEG-499
Page 1: ...PNEG 499 Cycle Plus Pan Feeder Installation and Operation Manual PNEG 499 Date 01 01 15...
Page 2: ...2 PNEG 499 Cycle Plus Pan Feeder...
Page 48: ...48 PNEG 499 Cycle Plus Pan Feeder NOTES...
Page 52: ...52 PNEG 499 Cycle Plus Pan Feeder NOTES...
Page 53: ...7 Parts List PNEG 499 Cycle Plus Pan Feeder 53 Grilled Centerhouse Control Unit Components...