5. Delay Time
10
PNEG-1640
Smart IR Sensor
Setting/Adjusting the Delay Time
To adjust the delay time setting, at any time, while pushing and holding the “On Delay Time” button, push
either the “arrow up” or “arrow down” button. Each time an “arrow” button is pushed, the time will change
by 1 minute. To make the time scroll faster, continue to hold the “arrow” button down for several seconds.
Figure 5B Adjusting the Delay Time
Delay Time Operation
Once the yellow “Product Detected” indicator light goes off, the delay time will begin to count down from
its maximum setting. During this time, the green “Auger” indicator light will flash. After the delay time
reaches 0.00, the “Auger” indicator light will turn on solid and the Flex-Flo system will start.
Delay Time By-Pass
When the Smart IR Sensor is in delay time, the green “Auger” indicator light will be flashing. It is not
necessary to wait for the delay time to expire before the auger will start-up. To make the auger start
immediately, by-pass the delay time for one cycle only, by pressing and holding the “On Delay Time”
button down for 5 second.
Summary of Contents for PNEG-1640
Page 1: ...PNEG 1640 Smart IR Sensor Installation and Operation Manual PNEG 1640 Date 12 21 11...
Page 2: ...2 PNEG 1640 Smart IR Sensor...
Page 15: ...PNEG 1640 Smart IR Sensor 15 NOTES...
Page 16: ...16 PNEG 1640 Smart IR Sensor 8 Replacement Parts Smart IR Sensor Assembly FLX 4951...
Page 18: ...18 PNEG 1640 Smart IR Sensor 9 Wiring Diagrams Alarm Wiring Diagram...
Page 19: ...9 Wiring Diagrams PNEG 1640 Smart IR Sensor 19 AP Wiring Diagram...
Page 20: ...9 Wiring Diagrams 20 PNEG 1640 Smart IR Sensor AP Wiring Diagram Continued...
Page 21: ...9 Wiring Diagrams PNEG 1640 Smart IR Sensor 21 Choretime Wiring Diagram...
Page 22: ...9 Wiring Diagrams 22 PNEG 1640 Smart IR Sensor Universal Wiring Diagram...