36
EXPERT WW rev.12
EXPERT WW
Standard Intensity —
Set the normal light
intensity of the light cycle. This parameter
ranges from the minimum light intensity to
100%. *
This parameter is accessible if the “lights
on 24 hours” option is disabled above.
Use Light Peaks? —
Select
“Yes”
to use light
peaks or select
“No”
to disable them.
Peak Cycle —
Select how much time is re-
quired to perform a light peak cycle (see previ-
ous graph). The
“Cycle Time”
must be even or
longer than the peak du peak sunrise
+ peak sunset. *
This parameter is accessible if
light peaks are enabled above.
Peak Duration —
Select during how much
time the light peak intensity must be main-
tained (from 1 to 59 minutes). *
This parameter
is accessible if light peaks are enabled above.
Peak Intensity —
Set the light peak intensity
to the desired value. It ranges from the “Stan-
dard Intensity” parameter value to 100%.
*
This parameter is accessible if light peaks are
enabled above.
Peak Sunrise / Sunset —
Select the duration
of the peak sunrise and sunset (see previous
graph). These parameters range from 1 to
60 minutes. *
This parameter is accessible if light
peaks are enabled above.
Light Relay Settings
This section explains how to set the intensity of
0-10V light outputs at which light relays
must turn on.
1. Select:
Main menu
Start/Stop
Light*
* This menu is accessible if light programs are used
(sec. 4.5).
9. CLOCK OUTPUTS
The controller has 2 outputs to control various
devices using the real-time clock. These clock
output can use up to 12 timer cycles.
A clock output starts when the
“On Time”
of a
timer is reached; it either stops after a certain
run time or at a certain time of day. The fol-
lowing diagrams show both possibilities:
Time
Cycle
Output
Status
On
Start Time
(e.g. 8h30AM)
Time Clock:
Start/Stop Mode
Stop Time
(e.g. 9h00AM)
Off
Clock #x
Use to navigate
Clock Mode Start/Stop
1.
On Time
6:00A h:m
Off Time
6:00A h:m
[or]
Clock Mode Start/Run
1.
On Time
6:00A h:m
Run Time Hour
0
Minutes
0
Seconds
0
2. Set the following parameters:
Clock mode —
The clock mode allows stop-
ping a clock output at a certain time of the
day or after a certain run time. Select “
Start/
Stop”
to specify the time at which each cycle
starts and stops or select
“Start/Run”
to
specify the running time of each cycle. Note
that the
“Start/Run”
option allows stopping
cycles with more precision since this mode
allows adjusting the seconds.
On Time / Off Time or Run Time —
Set the
time at which each cycle starts then set the
moment at which each cycle ends.
Time
Output
Status
Cycle
Start Time
(e.g. 8h30AM)
Time Clock:
Start/Run Mode
Run Time
(e.g. 30m:15s)
On
Off
1. Select:
Main menu
Start/Stop*
Clock**
Clock #x
* A password may be required to access this menu.
** This menu is accessible if at least 1 clock output
is enabled in the Installation Setup (section 4.5).
Light Settings
Activate relay at: 0%
2. Set the following parameters:
Activate relay at —
Set the intensity of the
0-10V output at which light relays must
turn on.