8. Installation
PNEG-308
Purafire
25
Figure 8A
Installation of Non-Recirculating Type (Outdoor) Option
1. Before proceeding with installation, verify the stud and electrical raceways within the building’s wall
do not interfere with the heater’s wall mounting brackets, outlet ducting, electrical wiring or gas
supply piping.
2. Install the support brackets and outlet ducting per the instructions provided with the optional
outdoor kit.
3. This heater must be installed level, and a minimum of 24" from the ground such that the bottom air
intake is not restricted in any manner. Check with a level in both the lengthwise and
crosswise directions.
4. Install gas piping, electrical supply wiring and optional thermostat wiring in accordance with local
codes, or, in absence of local codes, with the National Electrical Code and ANSI/NFPA 70-1993
and the standard for the storage and handling of liquefied petroleum.
5. Install a sediment trap and a manual shut off cock to the heater’s gas inlet.
6. Check all gas connections for leaks, using a leak detector solution. Repair any gas leak before test
firing or placing this heater into service.
7. Install a manometer to the gas valve to verify that the gas pressure is within the range specified on
the heater’s nameplate.
Summary of Contents for C225
Page 21: ...PNEG 308 Purafire 21 6 Wiring Diagrams 120V Models Figure 6A...
Page 22: ...22 PNEG 308 Purafire 6 Wiring Diagrams 220V Models Figure 6B...
Page 23: ...PNEG 308 Purafire 23 7 Wiring Harness Wiring Harness Assembly Figure 7A...
Page 32: ...32 PNEG 308 Purafire 11 Parts List C225 NG LP Galv Purafire 120V 60 Hz...
Page 34: ...34 PNEG 308 Purafire 11 Parts List C225 X1 NG LP Galv Purafire 220V 50 60 Hz...
Page 36: ...36 PNEG 308 Purafire 11 Parts List C80M NG LP Galv Purafire 120V 60 Hz...
Page 38: ...38 PNEG 308 Purafire 11 Parts List C80M X1 NG LP Galv Purafire 220V 50 60 Hz...
Page 56: ...56 PNEG 308 Purafire NOTES...