background image

INSTALLATION AND OPERATION MANUAL

MF3600G, MF3600S, MF3600B Models

Page 7

800-345-6007

CumberlandStoveWorks.com

 CAUTION

THIS  IS  A  MINIMUM  REqUIREMENT  FOR  SOOT 
AND  FLY  ASH  REMOVAL.  ASHES  SHOULD  BE 
PLACED  IN  A  METAL  CONTAINER WITH  A TIGHT 
FITTING  LID. THE  CONTAINER  SHOULD  BE  PLACED 
ON  A  NON-COMBUSTIBLE  FLOOR,  WELL  AWAY 
FROM  COMBUSTIBLE  MATERIALS,  PENDING  FINAL 
DISPOSAL. IF ASHES ARE DISPOSED OF BY BURIAL 
IN SOIL OR OTHERWISE LOCALLY DISPERSED, THEY 
SHOULD BE RETAINED IN THE CLOSED CONTAINER 
UNTIL ALL CINDERS ARE NO LONGER WARM.

DAILY MAINTENANCE

The  surfaces  of  the  stove  may  be  hot.

  Always  wear 

protective gloves even when the stove is cool to the touch. 
There are two areas that require daily maintenance; (1) the 
firebox and (2) the fire pot. 
•  Remove  the  top  baffle  inside  the  firebox  and  clean 

the fly ash and soot on all exposed parts using a steel 
brush and ash cleaning vacuum. The use of a shop-vac 
is not recommended. Talk to any authorized dealer for 
information about an ash cleaning vacuum.

•  The fire pot and the area around it are cleaned using the 

special tool provided with the stove and an ash cleaning 
vacuum. It is important to remove any unburned pellets 
that may have fallen behind the burn pot. 

•  Complete the daily maintenance by checking the seal 

on the doors. Look for pellets that may have been left 
behind during loading. Check that each of the door seals 
are flush with the stove and sealing properly. 

WEEkLY MAINTENANCE

•  To clean fire pot with cleaning tool, remove fire pot by 

unscrewing  the  small  spring  from  the  lower  cleaning 
rod. Remove rod and pull out fire pot. Hang on to end 
of cleaning tool with the hole in it. Scrape the fly ash 
that has fallen through the holes of the plate in the gap 
that sits below the fire pot. 

•  Remove the ash pan and dump the ash into a metal 

container. 

•  Cleaning of the exhaust system will depend upon the 

ash and debris content of your fuel. If your fuel has a high 
ash content and/or significant debris in it, the exhaust 
system will require weekly cleaning. Cleaner fuels will 
allow for monthly cleaning of the exhaust system. If you 
have installed clean out tees you will need to check for 
cleanliness. 

  note: a clean unit burns efficiently and will remain 

trouble free!

SEASONAL CLEANING

Once every year you must clean out all of the fuel in the 
hopper, firebox area, ash pan and fire pot area. Corn and 
any ash can accumulate moisture over the summer months 
causing the unit to rust and the fuel to mold. 
It is recommended that prior to shutting down the unit in 
the spring it is run on the high setting for about six hours to 
help clean out the heat exchanger system, venting system 
and firebox area. 

AIR FILTER

Air Filter Placement - back view

 WARNING

WHEN  PERFORMING  ANY  INTERNAL  ELECTRICAL 
MAINTENANCE 
•   MOVING  PARTS  INSIDE  OF THE  CABINET  MAY 

CAUSE  INJURY.  DO  NOT  OPERATE  UNIT WITH 
PANELS REMOVED OR OPEN. 

•  HOT  PARTS.  DO  NOT  OPERATE THE  UNIT WITH 

PANEL OPEN. 

•  RISk OF ELECTRIC SHOCk. DISCONNECT POWER 

BEFORE SERVICING UNIT. 

•  IN THE EVENT OF COMPONENT FAILURE, REPLACE 

WITH THE ORIGINAL FACTORY EqUIPMENT.

Reviews: