Culligan® Premier Series Automatic Deionizer
86
Cat. No. 01024000
Appendix F Optional Accessories
Conductivity Meter Quality Monitor
An external quality monitor/controller model number BL983320-1 (P/N 01023679) 120/230VAC can be used in place of
the standard AutoDI TDS probe. Any monitor/controller with a dry contact output that signals if the quality is above or
below a set point can be used, but Culligan offers optional quality monitior P/N 01023679, which reads 0-200 uS/cm and
can be easily installed into the GBE Smart Controller.
Functional Description—Front Panel
Figure 36.
Conductivity meter.
1. Liquid Crystal Display
2. Switch for selecting Alarm Mode
OFF = Alarm Disabled
AUTO = Automatic alarm based on set point value
ON = Alarm always active
3. MEAS—push button to set instrument to measurement
mode
4. SET—push button to display and set the set point value
5. SET—trimmer pot to adjust set point value
6. CAL—calibration trimmer pot
7. LED indicator:
GREEN = Meter in measurement mode
ORANGE/YELLOW = Alarm activated
RED (Blinking) = Error condition
Functional Description—Rear Panel
Figure 37.
Conductivity meter.
1. Connections for Conductivity Cell
2. Power supply for terminal strip
3. Alarm or Dosing contact: closes upon bad quality. See
4. Not used
5. Remove this jumper during installation.
6. Not used