14
Culligan® Premier Series Automatic Deionizer
14
Cat. No. 01024000
9. The system is equipped with diaphragm valves that are operated with solenoid valves using air pressure. The
air pressure must be at least 85 psi for proper operation of the diaphragm valves. Connect tubing from dia-
phragm valves to the appropriate solenoid valve port. Refer to
for proper connections.
WARNING! Air pressure must not exceed the maximum 100 psi.
Table 2. Deionizer resin and gravel quantities.
Model
Cation Resin
Quantity (ft
3
)
Anion Resin
Quantity (ft
3
)
Gravel per Tank
Quantity (lbs.)
QS-21
5
6
100 (2 bags)
QW-21
6
5
100 (2 bags)
QS-24
9
9
150 (3 bags)
QW-24
9
8
150 (3 bags)
QS-30
14
15
250 (5 bags)
QW-30
15
13
250 (5 bags)
QS-36
21
22
300 (6 bags)
QW-36
22
19
300 (6 bags)
QS-42
26
29
400 (8 bags)
QW-42
29
24
400 (8 bags)
QS-48
36
39
500 (10 bags)
QW-48
39
34
500 (10 bags)
10. Slowly pressurize the system and check for leaks. If leaks are found repair as needed.