11
01023492 F 06/19
The following information can be displayed at the control valve or remote display. These settings are
read-only. Press or to scroll through the settings. Press to view the previous setting.
Screen Display
Range
Setting Description
FILTERING
JAN-01-19 11:19A
N/A
1. From the
HOME
screen, press to view the main menu.
>1)INFORMATION
2)MANUAL MODE
1–6
2. The screen displays the main menu. Press to
select
1)INFORMATION
.
FILTER LIFE LEFT
50000 GAL
0–
50,000
3. The screen displays the
FILTER LIFE LEFT
in gallons.
Press to select the next information screen.
FILTER LIFE LEFT
100 DAYS
0–100
4. The screen displays the
FILTER LIFE LEFT
in days.
Press to see the next information screen.
REMAIN CAPACITY
700 GAL
0–no
limit
5. The screen displays the filtering capacity remaining,
measured in gallons (liters), before initiating
reconditioning. Press to see the next information
screen.
CURRENT FLOWRATE
10.0 GPM
0–no
limit
6. The screen displays the current flow rate, measured in
gallons (liters) per minute. Press to see the next
information screen.
TODAY’s USAGE
100 GAL
0–no
limit
7. The screen displays today’s water usage, measured in
gallons (liters). Press to see the next information
screen.
AVERAGE DAILY
300 GAL
0–no
limit
8. The screen displays average water usage for this
configuration. Press to see the next information
screen.
NEXT REGEN ON
JAN-03
N/A
9. The screen displays the date of the next regeneration,
based on average daily water usage. Press to see
the next information screen.