Culligan® 

Gold Series™ 

Automatic 

Water Softener 

Owners Guide

01018854_RevE

DCO 190420 05/19

©2019 Culligan International Company

Summary of Contents for Gold 10"

Page 1: ...Culligan Gold Series Automatic Water Softener Owners Guide 01018854_RevE DCO 190420 05 19 2019 Culligan International Company...

Page 2: ...2 01018854 E 05 19 This page intentionally left blank...

Page 3: ...16 Error Codes 17 When and How to Bypass Your Water Softener 18 Things to Check Before You Call for Service 19 Parts List Gold Series Softener Valve 20 Parts List Power Valve Service Parts List 21 Pa...

Page 4: ...ollow directions could result in damage to equipment or property Example CAUTION Disassembly while under water pressure can result in flooding Warning is used to indicate a hazard which could cause in...

Page 5: ...n the prestigious Culligan Gold Series With Culligan s many years of knowledge and experience in water treatment you can be confident that the model you selected has been designed and engineered to pr...

Page 6: ...in 59 in Salt Storage Capacity 250 lb or 375 lb 375 lb 375 lb 600 lb Rated Service Flow Pressure Drop 9 0 gpm 14 psi 9 4 gpm 15 psi 10 0 gpm 15 psi 10 6 gpm 15 psi Auxiliary Service Flow Pressure Dro...

Page 7: ...eria Easier Housekeeping Gleaming Fixtures You ll be amazed at the marvelous difference Just a swish of the cloth and the bathtub or shower and fixtures are clean and sparkling Imagine no scouring No...

Page 8: ...ric or colloidal iron This type of iron is an undissolved particle of iron A softener will remove larger particles but they may not be washed out in regeneration effectively and will eventually foul t...

Page 9: ...des the molded bypass valve the interconnecting couplings and the assembly pins Refer to Figure 1 for system placement Set the media tank on a solid level surface near water drain and electrical facil...

Page 10: ...at additional salt can be dissolved to provide the brine solution that will be needed for the next regeneration cycle B The Mineral Tank contains the Cullex resin column Cullsan underbedding and an ou...

Page 11: ...rovides water savings by optimizing the amount of rinse water required to completely rinse out the resin bed Manual Regeneration Pressing and holding the regen button for 5 seconds will initiate an im...

Page 12: ...roducts are used the salt storage compartment will require less frequent clean out but you must check more frequently for bridging Regardless of what type of salt is used we recommend Culligan Brand S...

Page 13: ...mmended Preventative Maintenance Inspection Schedule The Culligan High Efficiency household water softener has been designed to provide a good consistent service life Routinely inspecting the system m...

Page 14: ...k remove it and place it in a clean container 5 Using the scoop dig out and discard as much remaining salt water and debris as possible 6 Remove the brine valve chamber by removing the screws on eithe...

Page 15: ...ay Program Key Depress to enter and move through the programming steps Regeneration Key Press and hold the key for three 3 seconds to initiate an immediate regeneration When pressed during programming...

Page 16: ...en the Soft Minder meter has recorded the passage of a predetermined number of gallons 2 When the Aqua Sensor Probe senses the hardness in the Cullex Media 3 At the preset time when the number of days...

Page 17: ...to be turning Press and hold Program key for 10 seconds ERR 3 Incorrect Cycle Position The control expects to be in a different position than that indicated by the Cam switch closures Press and hold P...

Page 18: ...ing away on vacation and do not want the unit to recharge Bypass Valve In the back of Culligan water softener is a Cul Flo Valv Bypass valve To bypass the unit turn the blue knob clockwise To return t...

Page 19: ...ly is working Open a tap ahead of the softener outside tap to see if you have any water pressure If you have water pressure check the bypass valve If it is in the Service position put it into the bypa...

Page 20: ...OWER ONLY 8 6 3 10 9 3 12 5 63 63 4 7 3 63 63 3 63 11 63 64 64 64 64 64 64 3 Parts List Gold Series Softener Valve 25 15 14 16 18 13 1 62 63 24 23 22 21 62 64 63 35 2 63 64 36 28 30 31 32 33 34 61 61...

Page 21: ...05 19 Parts List Power Valve Service Parts List 42 41 43A 43A 43A 47 40 43A 47 43 57 51 55 53 54 56 52 6 3 12 7 82 83 72 71 67 72 70 28 32 34 26 20 17 61 5 4 7 11 2 21 35 60 62 63 64 ONLY THE FOLLOWE...

Page 22: ...P0445797 Seal Eductor Port 10 Each Pack 18 00448126 Plug Body Rear 1 Each 19 P0448128 Clip Body Rear 10 Each Pack 20 P1017758 Drain Elbow Assembly 10 Each Pack 21 P0448853 Repl Eductor Sleeve Softene...

Page 23: ...ductor Rebuild Kit Softeners 1 Each 62 01016267 Rebuild Kit Brine Piston Seal Pack 1 Each 63 01016269 Seal Pack Bell Crank Kit 1 Each 64 01013033 Seal Pack Brine Cam Softeners 1 Each 67 01018760 Bypas...

Page 24: ...1011195 Top Strainer Wide Slot 10 ea Pack 1 3 P1009099 O Ring Manifold 50 ea Pack 1 4 01016176 Outlet Manifold 9 1 4 01014539 Outlet Manifold 10 1 4 01018846 Outlet Manifold 12 1 4 01016429 Outlet Man...

Page 25: ...tem Part Number Description 01018770 Brine System 156 lb 1 01018769 Replacement Tank 156 lb 2 Cover 156 lb 3 01018764 Salt Plate 156 lb 4 01018768 Brine Chamber 156 lb 5 01035282 Brine Valve 6 P102019...

Page 26: ...stem 250 lb 01018715 Brine System 375 lb 1 01018709 Replacement Tank 250 lb 01018716 Replacement Tank 375 lb 2 Cover 250 lb 01018717 Cover 375 lb 3 01018707 Salt Plate 250 lb 01018713 Salt Plate 375 l...

Page 27: ...em 2 5 4 1 3 Item Part Number Description 01018720 Brine System 650 lb 1 01018718 Replacement Tank 650 lb 2 01018719 Cover 650 lb 3 Salt Plate 650 lb 4 01018708 Brine Chamber 5 01035282 Brine Valve 6...

Page 28: ...bow 0 45 gpm 01018711 BLFC Elbow 0 8 gpm 2 P1020194 Brine Well Cap 24 Pack 3 P1020191 Retaining Clip 24 Pack 4 P1020192 Pin 24 Pack 5 P1020193 5 16 Nut 24 Pack 6 P1020190 Overflow Fitting w Nut 24 Pac...

Page 29: ...certified by IAPMO R T against NSF ANSI 372 CSA B483 1 and NSF ANSI Standard 44 for the effective reduction of hardness calcium and magnesium and barium radium as verified and substantiated by test da...

Page 30: ...nsistent basis The Culligan Gold Series 9 Water Softeners are certified by IAPMO R T against NSF ANSI Standard 372 CSA B483 1 and NSF ANSI Standard 44 for the effective reduction of hardness calcium a...

Page 31: ...onsistent basis The Culligan Gold Series 10 Water Softeners are certified by IAPMO R T against NSF ANSI Standard 372 CSA B483 1 and NSF ANSI Standard 44 for the effective reduction of hardness calcium...

Page 32: ...fteners are certified by IAPMO R T against NSF ANSI Standard 372 CSA B483 1 and NSF ANSI Standard 44 for the effective reduction of hardness calcium and magnesium and barium radium as verified and sub...

Page 33: ...rs are certified by IAPMO R T against NSF ANSI Standard 372 CSA B483 1 and NSF ANSI Standard 44 for the effective reduction of hardness calcium and magnesium and barium radium as verified and substant...

Page 34: ...consistent basis The Culligan Gold Series 12 Water Softeners are certified by IAPMO R T against NSF ANSI Standard 372 CSA B483 1 and NSF ANSI Standard 44 for the effective reduction of hardness calciu...

Page 35: ...bstantiated by test data The Culligan Gold Series 14 Water Softeners are tested and certified by WQA against NSF ANSI Standard 61 for material requirements To maintain product certification and ensure...

Page 36: ...Water Softeners are tested and certified by WQA against NSF ANSI Standard 61 for material requirements To maintain product certification and ensure uniform performance the product is retested on a co...

Page 37: ...ns are furnished with each water conditioning unit TO THE EXTENT PERMITTED BY LAW CULLIGAN DISCLAIMS ALL IMPLIED WARRANTIES INCLUDING WITHOUT LIMITATION WARRANTIES OF MERCHANTABILITY AND FITNESS FOR P...

Page 38: ...38 Notes 01018854 E 05 19...