10
TROUBLESHOOTING
LEAKS AT FILTER/RO INLET OR OUTLET CONNECTION:
A rolled o-ring can block the tube from fully inserting. Use small screw driver to re-seat the o-ring
and then confirm that the end of the tubing has a clean, square cut.
LOW FILTERED WATER FLOW/SYSTEM RETURNS TO UNFILTERED FLOW AUTOMATICALLY:
Low flow rates may not activate the control box electronics. Refer to your system manual to trouble
shoot a low flow condition.
BUTTON IS COMMUNICATING BUT NO CHANGE IN FLOW:
Confirm that the bypass valve is in the down/closed position.
BUTTON COMMUNICATION IS INTERMITTENT:
Some materials may block the wireless signal more than others. Try moving the button to an area on
the counter that is closer to the under-sink control box.
FILTERED WATER FLOW WON'T TURN OFF: Low batteries for the control box can cause the system
to be stuck in the filtered position. The bypass valve can be used to allow unfiltered water flow to the
faucet while the issue is being corrected.