CULITEK MDP-47 Instruction Manual Download Page 3

BEFORE INSTALLING, PLEASE MAKE SURE:

If the unit has recently been transported do not use for a minimum of 24 hours before installing.

Make sure that the unit is at the desired temperature before loading it with product.

Ensure that the unit will have proper ventilation in the area that it will operate.

Inspect the unit to verify all accessories (shelves, shelf clips) are equipped with the unit before proceeding with installation.

Review the entire manual in its entirety. Lack of maintenance or misuse of the unit will void the warranty.

To minimize shock and 

fi

 re hazards, be sure not to over load the outlet. One outlet should be designated to the unit only.

Do not use extension cords.

Do not put hands under the unit when moving.

When the unit is not being used for an extended period of time, unplug the unit from the outlet.

After unplugging the unit, wait at least 10 minutes before re-plugging it. Failure to wait the allotted time may cause damage to

the compressor.

To minimize shock and/or 

fi

 re hazards, be sure not to plug or unplug the unit with wet hands.

Before any maintenance or cleaning, unplug the unit as a precaution.

To minimize shock and 

fi

 re hazards, make sure that the unit is properly grounded.

Do not attempt to remove or repair any component.

Make sure that the unit is not resting on or against the electrical cord or plug.

Do not hang or lean against door as this may cause personal injury or damage to the door hinge.

Do not store any 

fl

 ammable and/or explosive gas or liquids inside the unit.

Do not attempt to alter or tamper with the electrical cord.

Do not set the desired temperature out of the recommended temperature range: 

(FREEZER:-8°F – 20°F)

CABINET LOCATION GUIDELINES

Install the unit on a 

fl

 at sturdy surface

Unit may make abnormal noises if surface is uneven

Unit may malfunction if surface is uneven

Install the unit in an indoor, well-ventilated area with a 

fl

 oor drain nearby

Unit performs more ef

fi

 ciently in a well-ventilated area

For optimal performance, maintain a clearance of at least 6” around all sides

Outdoor use may cause decreased performance and may damage the unit

Avoid installing the unit in a high humidity and/or dusty area

Exposure to humidity may cause the unit to rust and/or decrease the ef

fi

 ciency of the unit.

Dust build up on the condenser coil will cause the unit to malfunction. Clean the condenser at least once a month

with a brush or clean cloth. Neglect of maintenance will void the warranty.

Select a location away from heat and moisture generating equipment

High ambient temperatures will cause the compressor to overcompensate, leading to higher energy bills and
eventual break down of the unit. With the lid open, the unit should not be used in areas of 80 degrees. The unit should
not be used in areas over 90 degrees.

Malfunction due to high temperatures will void the warranty.

ELECTRICAL

Please ensure that the required voltage of the compressor is constant at all times. Low or high voltage can detrimentally affect 
the unit and there by void its warranty.

All units should be plugged into a grounded and properly-sized electrical outlet with an appropriate over current protection. 
Please refer to the electrical requirements on the serial tag located inside the unit. Please make sure that the unit has its own 
dedicated outlet. Do not use an extension cord.

WARNINGS

INSTALLATION

Dipping Cabinets

A Professional Line of Commercial 

Refrigerated

 Equipment

Summary of Contents for MDP-47

Page 1: ...ipping Cabinets MODELS MDP 47 MDP 67 This manual contains important information regarding your Culitek unit Please read this manual thoroughly prior to equipment set up operation and maintenance Failu...

Page 2: ...DU PROPRI TAIRE GUIDE DE R PARATION AVANT DE TENTER UNE R PARATION TOUTES LE MESURES DE S CURIT DOIVENT TRE RESPECT ES CAUTION RISK OF FIRE OR EXPLOSION DUE TO PUNCTURE OF REFRIGERANT TUBING FOLLOW H...

Page 3: ...of the recommended temperature range FREEZER 8 F 20 F CABINET LOCATION GUIDELINES Install the unit on a flat sturdy surface Unit may make abnormal noises if surface is uneven Unit may malfunction if s...

Page 4: ...rmance unit should be placed into a defrost when the thickness of the ice on the cabinet wall reaches 1 4 To defrost the unit must be free of product and left unplugged or put in a manual defrost cycl...

Page 5: ...EANING THE INTERIOR OF THE UNIT When cleaning the cabinet interior use a mixture of mild soap and warm water It is not recommended to use steel wool caustic soap abrasive cleaners or bleach as this ma...

Page 6: ...tion of gasket and replace if necessary Clean the condenser coil Unplug unit and allow coil to defrost Make sure thermostat is not set too cold Ensure the door gasket s are sealing properly Unit is to...

Page 7: ...tated above Culitek warrants its sealed compressor to be free from defects in both material and workmanship under normal and proper use and maintenance service for a period of three 3 additional years...

Page 8: ...ANY WARRANTY OF MERCHANTABILITY OR LABOR COVERAGE FOR COMPONENT FAILURE OR OTHER THE WARRANTY PACKET PROVIDED WITH THE UNIT ALTERATION NEGLECT ABUSE MISUSE ACCIDENT DAMAGE DURING TRANSIT OR INSTALLAT...

Page 9: ...l number of the unit the serial number and dated proof of purchase Outside U S and Canada This warranty does not apply to areas outside the continent of the United States Culitek is not responsible fo...

Reviews: