CULITEK F1SS Instructional Manual Download Page 6

 

 

Page 5 

2. PREFACE (continued) 

 
WARNING:  RISK OF FIRE/FLAMMABLE MATERIALS  

 

CAUTION:    RISK OF FIRE AND FLAMMABLE REFRIGERANT R290 
 

If you need the electronic version instruction manual, please ask the manufacturer or its service agent. 

▲  Maximum load of shelf is 176 pounds 

 

This instruction manual provides all the necessary information regarding: 
▲   Use of the reach-in 
▲   Technical specifications 
▲  Installation and handling 
▲  Operator procedures and instructions 
▲   Maintenance operation 

 

The manual is to be considered an integral part of the unit and should be stored in a safe place for further 
consult to permit a good working life of the unit. Unit is intended for commercial use only. 

 

p

  Component parts shall be replaced with like components and servicing shall be done by factory  

  

authorized service personnel. 

 

The manufacturer cannot be held liable in the following cases: 

p

  Improper installation (not in accordance with the guidelines indicated herein) 

p

  Misuse of the unit 

p

  Power supply defects 

p

  Improper or inadequate maintenance 

p

  Unauthorized modification or tampering 

p

  Use of non-original spare parts 

p

  Partial or total failure to comply with the instructions 

 

All electrical equipment can be hazardous to health. Current standards and legal requirements must be 
complied with during the installation and use of any equipment. 

 

3. Use of Equipment

 

The unit is for preserving fresh perishable food, with a built-in refrigerated unit. Do not utilize the 
equipment to store medical supplies. The optimum operational temperatures are between  
33

°

F to 40

°

F in refrigerators and -8

°

F to 0

°

F in freezers. 

 

4. Technical Features 

The unit is a ventilated system; the evaporator is in a separate insulated box on the top. All the materials 
used in the manufacture of this unit are guaranteed to be suitable for use with food. Eco-friendly R290 
hydrocarbon refrigerant. The refrigerating circuit is in compliance with the current normative 
 

5. Operation 

The gas in the refrigerating circuit is compressed, liquefied and evaporated in the ventilated evaporator, 
which is situated on the top of the container. 

 

This cycle involves the absorption of heat from the air in the refrigerator compartment and the reason is 
cooled

The heat produced is dissipated to the outside environment by a condenser unit located on the 

top of the unit.  

Summary of Contents for F1SS

Page 1: ...F2SS F3SS This manual contains important information regarding your Culitek unit Read this manual thoroughly prior to equipment setup operation and maintenance Failure to comply with regular maintena...

Page 2: ...ntrol Unit 6 7 Handling 6 8 Installation Procedure 6 9 Connecting to Main Power Supply 6 10 Maintenance Instructions 7 11 Troubleshooting 7 12 Technical Service 7 13 Configuration Sketch Map 7 14 Oper...

Page 3: ...n to the two 2 year warranty Culitek warrants its sealed compressor to be free from defects in both material and workmanship under normal and proper use and maintenance service for a period of three 3...

Page 4: ...is not responsible for repair or replacement of failed or damaged components resulting from electrical power failure the use of extension cords low voltage or voltage drops to the unit The two 2 year...

Page 5: ...and pulling on the plug top p Do not pull out the cord or touch the power plug with wet hands Clean water or dust from the power plug and insert it with the ends of the pins securely connected p Do n...

Page 6: ...tampering p Use of non original spare parts p Partial or total failure to comply with the instructions All electrical equipment can be hazardous to health Current standards and legal requirements must...

Page 7: ...ear heat sources or in direct sunlight Remove the straps securing the cardboard packing the cardboard covering and the PET protection film before installation Clean the unit with mild detergent and th...

Page 8: ...ean the condenser regularly a minimum of once every 4 months with a dry brush or vacuum cleaner 11 Troubleshooting Unit stops working light off Power supply failure Remedies Check that the plug is ins...

Page 9: ...reases the displayed value In programming mode it browses the parameter codes or decreases the displayed value Lock or unlock keyboard To enter in programming mode To return to room temperature displa...

Page 10: ...according to Cy e Cn P2 Evaporator probe failure Defrost end is timed HA Maximum temperature alarm Outputs unchanged LA Minimum temperature alarm Outputs unchanged EA External alarm Outputs unchanged...

Page 11: ...Page 10 ELECTRICAL CONTROL CIRCUIT DIAGRAMS Refrigerator...

Page 12: ...Page 11 ELECTRICAL CONTROL CIRCUIT DIAGRAMS Freezer...

Page 13: ...Page 12 ELECTRICAL CONTROL CIRCUIT DIAGRAMS Three Door Freezer...

Page 14: ...Page 13 TECHNICAL PARAMETERS Bottom Mount Reach Ins NOTE Technical data subject to changes...

Page 15: ...Page 14 OFFICIAL APPROVAL RULES Conforms to UL STD 471 Certified to CSA STD C22 2 NO 120 Conforms to NSF AMSI STD 7...

Reviews: