In
more
detail...
All installation work must be carried out by a
competent person or qualified electrician.
Before connecting the mains supply ensure that
the mains voltage corresponds to the voltage on
the rating plate inside the cooker hood.
Warning:
THIS APPLIANCE MUST
BE EARTHED
.
Mains Supply could be connected to the Mains Voltage by Direct
Connection
Direct Connection
If the appliance is being connected directly to the mains an
omnipolar circuit-breaker must be installed with a minimum
opening of 3mm between contacts.
If the cable is damaged or to be replaced, the operation must be
carried out the by a qualified electrician with dedicated tools to
avoid any accidents.
The installer must ensure that the correct electrical connection has
been made and that it complies with wiring diagram.
The cable must not be bent or compressed.
The cable must be checked regularly and replaced by authorized
technicians only.
DOUBLE POLE SWITCHED
FUSED SPUR OUTLET
USE A 3AMP FUSE
FUSE ON
USE A 32 AMP FUSE
Technical and legal
information
18