Fault
Cause
Solution
Light on, but
motor does not
work.
Fan switch turned off.
Select a fan switch position.
Fan switch failed.
Contact service center.
Light on, but
motor does not
work.
House fuses blown.
Power cord loose or
disconnected.
Oil leakage.
One way valve and the air
ventilation entrance are
not tightly sealed.
Take U-shaped section down and
seal.
Leakage from the
connection of U-shaped
section and cover
.
The distance between the
range hood and the gas
top is too far.
Refit the range hood to the correct
distance.
Take down the one way valve and
seal with sealant.
Lights not
working.
Broken/Faulty globes.
Replace globes as per this
instruction.
The fixing screw not tight
enough.
Tighten the hanging screw and
make it horizontal.
The Range hood
inclines
Motor failed.
Contact service center.
Reset/Replace fuses.
Refit cord to power outlet.
Switch power outlet on.
Insufficient
suction
Summary of Contents for UBADCH110BK