21
In
more
detail...
Technical and legal
information
Electrical Requirements
Any permanent electrical installation must comply with the latest
I.E.E. Regulations and local electricity company regulations. For
roll of the National Inspection Council for Electrical Installation
Contracting (NICEIC) should undertake the electrical installation.
Electrical Connection
Before connecting the mains supply ensure that the mains
voltage corresponds to the voltage on the rating plate inside
the appliance.
WARNING: THIS APPLIANCE MUST BE EARTHED
The appliance is supplied with a 3-core mains cable and must be
connected to the electricity supply via a double pole switch having
a 3mm minimum contact gap on each connector.
The wires in the mains lead are coloured in accordance with the
following code:
Brown = L - Live
Blue = N - Neutral
The connection point must be placed in a position adjacent to the
appliance so as to be readily accessible for an engineer in the
event of a breakdown.
Disconnect the appliance from the mains supply before
carrying out any kind of maintenance or cleaning.
> Connect the appliance to the power supply (220 to 240 V~ / 50 Hz).
> The socket should be connected in compliance with the relevant
standard to a single-pole circuit breaker.
>
NOTE: • Make sure that power supply rating is correct for the appliance.
• Installed with a minim
um gap of 3 mm between contacts.
Caution
The surface of the appliance becomes quite hot
when operating.
This could alter the electrical insulation and could
cause electricity leakage.
Summary of Contents for ICONCER60RF
Page 1: ...Ceramic Hob MODEL ICONCER60RF Touch Control Instruction Manual...
Page 3: ...3 Installation Installation 21 ICONCER60RF Touch Control Ceramic Hob...
Page 5: ...5 Getting Started Getting started Before you start 06 Safety 07...
Page 13: ......
Page 23: ...Installation Appendix Appendix 23...
Page 29: ...Notes 29...