CUES, INC.
800.327.7791 | [email protected] |
www.cuesinc.com
16
POSSIBLE SYMPTOMS
Indicator
Low Battery
Extreme
Temperature
Internal Pressure
Internal Humidity
All Spot Lights
ON
N/A
Low temperature
warm up (no video)
N/A
N/A
Power Switch
Flashes 5x/sec
Low battery
(~30%)
High temperature
warning
High internal
pressure
(Submersion > 1m)
High internal
humidity (Greater
than ~85%; no
video)
Power Switch
Flashes 2x/sec
Very Low Battery
(~20%)
High temperature
error (no video)
N/A
N/A
Power Switch
Flashes 1x/sec
Critically Low
Battery (<2%)
High temperature
startup (no video)
N/A
N/A
TROUBLESHOOTING THE QZ3
QZ3 SOFTWARE UPDATES
IMPORTANT! VISIT HTTPS://CUESINC.COM/PAGES/QZ3-SOFTWARE-UPDATES
REGULARLY TO CHECK FOR THE LATEST SOFTWARE UPGRADES FOR YOUR QZ3.
!
BASIC TROUBLESHOOTING CHECKS
•
Ensure tablet or other connected device is connected to QZ3 Wi-Fi network (needs to be
connected at each power up)
•
Power cycle camera
•
Change batteries
•
Close all applications on tablet/connected device
•
Close all tabs in web browser (Google Chrome is recommended)
•
Clear Google Chrome browser cache
•
In the browser select three vertical dots on upper right corner of screen>Settings>Privacy>Clear
Browsing Data>Clear Data (ensure time range “all time” is selected
•
Perform any required updates to tablet/connected device
•
Power cycle tablet/connected device