Cub VS-60U024 Series Manual Download Page 1

 

0

 

 

  

  

 

CUB SENSOR AID DUO TPMS 

TOOL

 

 
 

For VS-60U024 / VS-60U029 Series 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Brand Name : 

Cub

 

Model Name

 : VS60U029

 

Product Name

 : Sensor AID DUO TPMS 

TOOL

 

Summary of Contents for VS-60U024 Series

Page 1: ...0 CUB SENSOR AID DUO TPMS TOOL For VS 60U024 VS 60U029 Series Brand Name Cub Model Name VS60U029 Product Name Sensor AID DUO TPMS TOOL ...

Page 2: ...ppearance 1 2 Keypad Summary 2 Function 2 1 MAKER SELECTION 2 1 1 DIAGNOSE 2 1 2 PROGRAMMING 2 1 3 CHECK UNI SENSOR 2 1 4 RELEARN INFO 2 1 5 OBD II OPTIONS 2 1 6 TREAD DEPTH 2 2 LAST VEHICLE 2 3 SETTINGS 2 4 UPDATE 2 5 SAVED VEHICLES 2 6 TOOL INFORMATION 3 Warranty 2 3 4 5 14 14 17 20 20 21 ...

Page 3: ...A Max 600 mA Operating Temperature 0 40 32 104 Storage temperature 20 60 4 140 Operating Humidity 20 90 Storage Humidity 20 90 Size rubber 210 102 62mm Weight 630g 5 60U029 series 610g 5 60U024 series NO Item Q ty 1 Sensor Aid TOOL 1 2 OBD II cable 1 3 Charger 5V 2A 1 4 Mirco usb cable 1 5 Magnet 1 6 User manual 1 7 BT OBD II 1 ...

Page 4: ...ressure sensor through wireless radio frequency communication to Retrieve data from tire pressure sensor Verify the identity of each tire pressure sensor mounted on the wheels Assist technicians in servicing CUB Uni Sensor during relearn procedures NOTE Sensor shall be diagnosed close to left or right antenna 1 1 Appearance 1 2 Keypad Summary Power On Off Navigate through measured and parameters b...

Page 5: ...orange when charging Esc key press it to return to the previous menu without parameter validation Press and hold the power key for 3 seconds to power on the device During power on The device display the CUB logo Now the device is at the MAIN MENU RJ11 cable Function pending Home key Back to main menu Tread Depth mechanism This function is for the 60U029 series LED for Camera AF Camera ...

Page 6: ...n Use the arrow key to browse model press the OK key to select MAIN MENU Use the arrow key to browse function press the OK key to select FUNCTION selection Press the OK key to select DIAGNOSE function Press OK key to enter 2 1 MAKER SELECTION NOTE Definition OK key Select Validate Process 2 1 1 DIAGNOSE 2 1 1 1 Diagnose SINGLE SENSOR Arrow Key Use arrow keys to browse maker ...

Page 7: ...NOTE The Sensor AID will identify the sensor informationthat is transmitted Not all sensors transmit every piece of information shown 2 1 1 2 Diagnose MULTIPLE SENSORS The picture below is an example of sensor data communication result DIAGNOSE To diagnose sensor information PROGRAMMING a shortcut to the Programming menu See page 6 Sensor AID will now activate the sensor Sensor response time may v...

Page 8: ... SENSOR HINT IN CRADLE Indicates programming by wire Uni Sensor must be placed inside cradle WIRELESS Indicates programming by wireless Wireless Uni Sensor must be within programming range from the tool NOTE Make sure there are no other Wireless Uni Sensors within 1 m from the tool when you use wireless programming otherwise the programming will fail Program blank sensor When selected and pressing...

Page 9: ...ual Duplicate An instruction message will be displayed during 4 seconds then will automatically disappear 2 1 2 2 AUTO DUPLICATE DIAGNOSE If there is no existing data diagnose all sensors that you wish to duplicate at the beginning DUPLICATE Will be enabled when at least one sensor is diagnosed Select it and press OK to duplicated all previously diagnosed sensor PROGRAMMING a shortcut to the Progr...

Page 10: ...ied After source ID is detected key in new ID by means of the keyboard then select Modify and press OK key NOTE Duplicate and Programming functions will only work with CUB s Sensor AID and Uni sensor Duplicate To duplicate a manual ID to a Uni Sensor will be enabled after keying in first character HEX to DEC To change between HEX and DEC ID formats enabled at the beginning becomes disabled once fi...

Page 11: ... If a Wireless Sensor is detected the message above is displayed Press ESC key to go back Once source ID is detected select side to program to The above message confirms the successful side programming See step 2 1 2 then use arrow key to browse Press OK key to enter 2 1 2 5 L R 2 1 2 6 BACK TO MAKER MENU 2 1 3 CHECK UNI SENSOR Back to MAKER SELECTION ...

Page 12: ...ss OK key to enter 2 1 4 RELEARN INFO 2 1 5 OBD II OPTIONS BT disconnect BT connecting Note When you exit OBDII OPTION and back to OBDII OPTION immediately it will cost 5 10 second to re connect Function immediately starts scanning for a Uni Sensor Once detected the screen above is displayed Press OK key to scan the next sensor or ESC to go back Use up and down arrow keys to scroll ...

Page 13: ...12 Press OK key to enter Press OK key to enter Press OK key to enter Press OK key to enter 2 1 5 1 READ ID 2 1 5 2 WRITE ID 2 1 5 3 UNLOCK ECU for some certain vehicles Toyota ...

Page 14: ...n by simply selecting it in the matrix then pressing OK key 2 1 5 4 CLEAR DTC 2 1 5 5 BACK Back to MAKER SELECTION 2 1 6 TREAD DEPTH Alarm Do not use the Tread Depth function on anyone s eyes which can cause visual impairment SAVE Will enable when there is existing data 2 2 LAST VEHICLE This function is the shortcut to the last picked MMY Select it and the MMY will be displayed above the icon Pres...

Page 15: ...ts press the OK key to select See step 2 1 then use arrow key to browse Press OK key to enter Press the OK key to select Use the arrow keys to browse units press the OK key to select LEXUS CT 06 2014 12 2016 2 3 SETTINGS 2 3 1 PRESSURE UNIT 2 3 2 TEMPERATURE UNIT ...

Page 16: ... select Use the arrow keys to browse options press the OK key to select Press the OK key to select Use the arrow keys to browse languages press the OK key to select Press the OK key to select Use the arrow keys to browse regions press the OK key to select 2 3 3 ID FORMAT 2 3 4 AUTO OFF 2 3 5 LANGUAGE 2 3 6 REGION ...

Page 17: ...OK key to select Use the arrow keys to browse volume levels press the OK key to select Press the OK key to select Use the arrow keys to browse backlight levels press the OK key to select Press the OK key to select Use the arrow keys to adjust date and time then press OK to set 2 3 7 MUTE 2 3 8 VOLUME 2 3 9 BACKLIGHT 2 3 10 DAY TIME ...

Page 18: ...II pairing and then press OK key to select The pairing process begins immediately it may take several seconds Wait for the process to complete Once the paring is completed the above message is displayed 2 3 11 BT OBD II PAIRING 2 4 UPDATE Update tool by PC software Update BT OBD II Moudle Make sure BT Moudle is plug on a vehicle ...

Page 19: ...pdate Platform v1 7 beta2 lite zip 3 Execute Cub Updater exe 4 Connect Mico usb to TOOL and PC usb port 5 Click Download for auto update 5 1 SN is invalid You will see the error message Serial number 0000F0F10F00 cannot be found Please contact your distributor dealer Enter Appear connect ...

Page 20: ...ate please plug OBD II module into an OBD II connector of any vehicle in order to have the power source for the OBDII module Update Mode Cub_BT_OBDII OBDII is updating Reboot Download file from server Transmit file to tool Transmit completed Disconnect usb cable Wait for tool update ...

Page 21: ...ath DEL ALL Deletes all data DEL OLDEST Deletes oldest saved vehicle only DEL SELECTED Deletes selected saved vehicle only See step 2 1 then use arrow key to browse Press OK key to enter Tool information is displayed OS Operating Sytem H W Hardware F W Firmware MAC ADDRESS 2 5 SAVED VEHICLES DEL ALL DEL OLDEST DEL SELECTED 2 6 TOOL INFORMATION Update Complete ...

Page 22: ...lling a TPMS sensor new valves and screws should be used Warning Only use Cub autoparts replacement parts Using other brands will not allow the system to work and will void the warranty Caution Read these simple guidelines Not following them may be dangerous or illegal Read the complete user guide for further information SWITCH ON SAFELY Do not switch the device on when wireless use is prohibited ...

Page 23: ...erference will not occur in a particular installation lf this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna lncrease the separation between the equipment and receiver Connect th...

Page 24: ...d by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician...

Page 25: ...uillage et 2 l utilisateur de l appareil doit accepter tout brouillage adioélectrique subi même si le brouillage est susceptible d en compromettre le fonctionnement SAR IC RF Radiation Exposure Statement The product comply with the Canada portable RF exposure limit set forth for an uncontrolled environment and are safe for intended operation as described in this manual Déclaration d exposition aux...

Reviews: