3.3.11 OVERVOLTAGE
If the bus voltage rises above 15.3 volts, the voltage
annunciator will illuminate.
Master Switch ................................................................. Off
Wait one minute. Then, switch the master switch on and
monitor voltage. If the annunciator illuminates again, turn
the master switch off and plan to continue flight without
electrical system.
3.3.12 INADVERTENT SPIN
Aileron Control ......................................................... Neutral
Throttle ..................................................................... Closed
Rudder ............................................................ Full opposite
(Opposite to direction of spin)
Elevator ..................................................... Control Forward
(To break stall)
Elevator and Throttle ......................................... As required
(To resume level flight smoothly)
If flaps were down, retract once a safe flying speed has
been attained. Ensure that the flap speed is not
exceeded (81 mph or 70 knots IAS).
CAUTION
This recovery procedure is applicable only when the
aircraft is in a spin. Application of controls as
described above during a stall or after the aircraft
has stopped gyrating may cause the aircraft to enter
into a spin.