18
Tel:(86)-0755-86652921
ShenZhen Aviation intelligent technology Co, Ltd
Fax:(86)-0755-86652974
7
Configure IR carrier
frequency
>COM-IR-CLK:a<CR>
a = carrier (0~4) [33KHz,36KHz,38KHz,40KHz,56KHz]
8
IR learning IR code
>COM-IR-LEARN-CODE:a
<CR>
a = waiting time (1 ~ 20s)
9
Send test learned IR
code
>COM-IR-LEARN-TX:a,b
<CR>
a = port (0 ~ 2) [TX1, TX2, hdbt]_ TX]
b = IR code (optional, if NULL, send learning buffer)
IR coding management
Application scenario management instruction
1
Add application
scenarios
>APPS-ADD:a<CR>
a = name (can not repeat)
2
Delete application
scenario
>APPS-REMOVE:a<CR>
a = name
3
Modify application
scenario name
>APPS-MODIFY:a,b<CR>
a = old name
b = new name (can not repeat)
4
Adjust the position
of application
scenarios
>APPS-MOVE:a,c<CR>
b = current index position
c = 0: move up 1: move down
Summary of Contents for WP-MAC-E1