CTX S500 User Manual Download Page 20

 

S500/500B 

User’s Manual

 

 

20

English 

Video Modes

 

Resolution

 

VCLK(MHz)

 

Horizontal 

Frequency (KHz)

 

Refresh Rate 

(Hz)

 

Standard

 

640*350

 

25.175

 

31.469

 

70.000

 

IBM VGA

 

720*400

 

28.322

 

31.469

 

70.000

 

IBM VGA

 

640*480

 

25.175

 

31.469

 

59.940

 

IBM VGA

 

640*480

 

31.500

 

37.861

 

72.809

 

VESA

 

640*480

 

31.500

 

37.500

 

75.000

 

VESA

 

800*600

 

40.000

 

37.879

 

60.317

 

VESA

 

800*600

 

50.000

 

48.077

 

72.188

 

VESA

 

800*600

 

49.500

 

 

46.875

 

75.000

 

VESA

 

1024*768

 

65.000

 

48.363

 

60.004

 

VESA

 

1024*768

 

75.000

 

56.746

 

70.069

 

VESA

 

1024*768

 

78.750

 

60.023

 

75.029

 

VESA

 

 

Summary of Contents for S500

Page 1: ...S500 500B User s Manual 1 English U s e r s M a n u a l S 5 0 0 5 0 0 B ...

Page 2: ...f Contents 1 Important Safety Instructions 3 2 Introduction 8 3 Recommended Use of the Monitor 10 4 Controls and Adjustments 11 5 Energy Declaration 16 6 Trouble Shooting 17 7 Technical Information 19 8 Product Overview 21 9 Specifications 23 ...

Page 3: ...iver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Warning If a shielded type power cord is supplied with this monitor it is required in order to meet FCC emission limits and to prevent interference with nearby radio and television reception Only shielded cables should be us...

Page 4: ...ation of Professional Employees Svenska Naturskyddsforeningen The Swedish Society for Nature Conservation and Statens Energimyndighet The Swedish National Energy Administration Approval requirements cover a wide range of issues environment ergonomics usability emission of electric and magnetic fields energy consumption and electrical and fire safety The environmental demands impose restrictions on...

Page 5: ...t disturbances in foetus development may occur The relevant TCO 99 demand requires that plastic components weighing more than 25 grams must not contain flame retardants with organically bound bromine or chlorine Flame retardants are allowed in the printed circuit boards since no substitutes are available Cadmium Cadmium is present in rechargeable batteries and in the colour generating layers of ce...

Page 6: ...e reference 1 To clean the LCD Monitor screen make sure the Monitor is in the power off mode Unplug the Monitor from its power source before cleaning it Stand away from the LCD Monitor and spray cleaning solution onto a rag Without applying excessive pressure clean the screen with the slightly dampened rag 2 Do not place your LCD Monitor near a window Exposing the Monitor to rain water moisture or...

Page 7: ...itor to PC signal cord is frayed or damaged Liquid has been spilled into the Monitor or it has been exposed to rain The Monitor has been dropped or the case has been damaged 8 For use only with power supply FSP FSP048 1AD101C Linearity LAD6019AB4 Potrans SZADPT 030P Notice Actual safety specifications please refer to the label on the back of monitor ...

Page 8: ...pabilities and emits no X ray radiation The features are 15 TFT Liquid Crystal Display Compatible with IBM VGA VESA Direct RGB input XGA 1024x768 resolution up to 16M colors Lightweight compact design weighing less than 3 7Kg DPMS power saving Universal adapter power supply Anti glare display On Screen Display OSD controls and adjustments Package Overview Your monitor package contains LCD Monitor ...

Page 9: ... in case the need arises to store or transport the unit Let the LCD lie on its face when you put it into the carton Installation Monitor Arm The Monitor Arm is an optional item Step1 Step2 Step3 Step4 Step5 CAUTION The Arm Mounting Device must be VESA Flat Physical Mountiog Interface Stanard ...

Page 10: ...owever if another type of power cord is required power cord H05VV F or VW 1 18AWG x 3G should be used Do not overload wall outlets or power cords Ensure that the total of all units plugged into the wall outlet does not exceed 7 amperes Ensure that the total ampere ratings on all units plugged into the extension cord is not above the cord s rating If the power supply cord which came with your monit...

Page 11: ... personal preference Front User Controls S500 S500B 1 Enter button To display the OSD manual and select functions 2 Down button To adjust the selected OSD function or the brightness directly 3 Up button To adjust the selected OSD function or the contrast directly 4 ESC button To close the OSD manual and to escape function 5 Power LED Indicator As long as the monitor is powered this indicator is li...

Page 12: ...ll automatically adjust the clock phase H position and V position values for optimal settings ADVANCE AUTO TUNE PATTERN PROGRAM USING GUIDE As some VGA Card doesn t match the VESA standard It can t out put 0 7 V p p VESA standard Therefore we need ADVANCE AUTO TUNE PATTERN PROGRAM to modify the parameters of monitor to match different output level of VGA card Auto_tune exe This file includes in th...

Page 13: ...on in the OSD menu 2 Color You can choose either the 6500 K 9300 K colour temperature mode or User mode to store your user defined color settings User Mode Press button to enter User mode Press the or button to select the R G B gain then press button to proceed Finally press ESC button to leave this function 3 Image Here are some items can be adjusted as below please press enter the item menu ...

Page 14: ...50 or VGA Graphics mode 640x400 640x350 to get better picture performance Smoothing Press the Yes or No button to change smoothing 4 Position To adjust the Image or OSD position Image Position or OSD Position H Position Press the or button to reposition of the picture or the OSD window to the right or left V Position Press the button to moves the picture or the OSD window upwards and to move them ...

Page 15: ...nguage Press the or button to select between English French Italian Spanish or German languages 6 Recall Press the or button to select Yes or No Choosing Recall to callback all the settings for the current Input Signal mode to factory preset ...

Page 16: ...96 The time settings for switching to a power saving mode are adjusted from the system unit by software From the first indication of inactivity to power saving position A2 the total time must not be set to more than 70 minutes 1 VESA Power Management Proposal VESA DPMS Standard H sync V sync Video State Off On Blank Stand by On Off Blank Suspend Off Off Blank Off 2 Power Consumption 120 230 Vac NU...

Page 17: ...lly turn off as a result of the Power Saving feature Press any key to see if the screen comes back Refer to the Controls and Adjustments section to adjust the brightness BRIGHTNESS on the OSD sub menu The screen flashes when it initializes Turn off the monitor and turn it on again Refer to the Controls and Adjustments section to reload the default setting RESET on the OSD main menu Partial image o...

Page 18: ...l Text Graphics item switch to other mode Signal out of Range When the input signal is outside the normal specifications the screen will display an Signal Out of Range message No Signal Input The No Signal Input message indicates that the cable may not be plugged property into the host system WARNING Do not disassemble the monitor Contact your dealer if needed ...

Page 19: ...s This section provides you with detailed information on pin assignment of the D Sub connector and the preset timing chart of the prevailing video standards Pin Assignments Male Mini D 15 Connector Signal 15 Pin Mini D Sub Red Video 1 Green Video 2 Blue Video 3 Horizontal Sync 13 Vertical Sync 14 Ground 5 6 7 8 10 11 No Connection 4 9 SDA DDC 12 SCL DDC 15 ...

Page 20: ...VGA 720 400 28 322 31 469 70 000 IBM VGA 640 480 25 175 31 469 59 940 IBM VGA 640 480 31 500 37 861 72 809 VESA 640 480 31 500 37 500 75 000 VESA 800 600 40 000 37 879 60 317 VESA 800 600 50 000 48 077 72 188 VESA 800 600 49 500 46 875 75 000 VESA 1024 768 65 000 48 363 60 004 VESA 1024 768 75 000 56 746 70 069 VESA 1024 768 78 750 60 023 75 029 VESA ...

Page 21: ...S500 500B User s Manual 21 English Product Overview Front View unit mm Side View unit mm ...

Page 22: ...S500 500B User s Manual 22 English For viewing clarity you can tilt the LCD panel forward up to 5 degrees or backward up to 20 degrees Rear View unit mm ...

Page 23: ...l Contrast ratio 300 1 typical Response time 40ms User controls Power Enter Up Down Esc Power Consumption 35W Max 5W Power Saving Input signal Analog 0 7V peak to peak separate TTL Positive or Negative Power Supply 100 120 200 240 VAC 50 60 Hz automatically Plug Play DDC 2B Dimension Weight Size WxDxH 372 x 171 x 355 mm Weight net 3 7 Kgs Operating Environment Temperature 5 C 35 C Humidity 20 80 n...

Page 24: ...S500 500B User s Manual 24 English Humidity 10 90 non condensing Altitude 40 000ft Note Specifications are subject to change without notice ...

Reviews: