14
(parallel connection)
The two wires attached to the Fault contacts form an
open circuit when :
The IES has lost power from one of the DC power
inputs.
OR
One of the ports for which the corresponding Port Alarm
DIP Switch is set to ON be not properly connected.
2.6 Connecting the switch to Network
Connect to Network
This Industrial Ethernet Switch has 2 uplink ports (RJ-45 or SFP, please refer to
ordering information) and 4 downlink 10/100/1000Mbps RJ-45 ports for you to
implement it in your industrial environment. All RJ-45 ports can be inserted by
10/100/1000Base-T cables, connecting to the end devices. The fiber port(s) can accept
any kind of connector with proper SFP transceiver (mini-GBIC).
Figure 7.
Industrial Ethernet Switch general application