1.5 Cable Specifications 

The following table contains various cable specifications for the Managed Switch. Please make sure 
that you use the proper cable when connecting the Managed Switch. 

 

Cable Type 

Description 

10Base-T 

UTP Category 3, 4, 5 (100 meters max.) 
EIA/TIA- 568 150-ohm STP (100 meters max.) 

100Base-TX 

UTP Cat. 5 (100 meters max.) 
EIA/TIA-568 150-ohm STP (100 meters max.) 

1000Base-T 

UTP Cat. 5e (100 meters max.) 
UTP Cat. 5 (100 meters max.) 
EIA/TIA-568B 150-ohm STP (100 meters max.) 

100BASE-FX 

Multi-mode fiber module(2km) / Single-mode fiber 
module 

1000BASE-SX 

Multi-mode fiber module (550m) 

1000BASE-LX 

Single-mode fiber module (10km) 

1000BASE-LH 

Single-mode fiber module (30km/50km) 

1000BASE-ZX 

Single-mode fiber module (80km) 

SFP Transceiver 

SFP Transceiver for 1000BASE-SX Multi-mode fiber 
module (550m) 
SFP Transceiver for 1000BASE-LX Single-mode fiber 
module (10km) 
SFP Transceiver for 1000BASE-LH Single-mode fiber 
module (30km/50km) 
SFP Transceiver for 1000BASE-ZX Single-mode fiber 
module (80km) 

 

 

 

 
 
 
 

 

 

 
 
 
 
 
 
 
 

Summary of Contents for FOS-3110 Series

Page 1: ...FOS 3110 Series 10 port L2 Managed Gigabit Fiber Switch User s Guide Version 1 0...

Page 2: ...ful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference a...

Page 3: ...1 2 3 1 Desktop Installation 11 2 3 2 Rack Installation 12 2 3 2 1 Install a Single FOS 3110 Switch in a Rack 12 2 3 2 2 Install two FOS 3110 Switches in a Rack Using FOS Combine Kit 14 2 3 2 3 Instal...

Page 4: ......

Page 5: ...ly clearly introduce CTS FOS 3110 Managed Switch but tell you how to install this Managed Switch with detailed instructions Organization of the Manual Chapter 1 Introduction describes the features of...

Page 6: ...in the front panel This Managed Switch provides high performance store and forward switching capability plus other advanced features such as QoS VLAN Spanning Tree LACP and so on LED indicators locat...

Page 7: ...c address table 8K Memory buffer total 524K bytes VLANs support up to 2K VLAN Groups Support jumbo frame on all ports up to 9K bytes size QoS classification based on IEEE802 1p TOS DSCP 802 1Q Tunneli...

Page 8: ...k to the factory defaults and restart the system 4 Console Port An asynchronous serial console port supports the RS 232 electrical specification The console port can be used to manage the device and t...

Page 9: ...Managed Switch provides one fixed power module The type of power module is AC input The interface on the rear panel of the Managed Switch is described below 7 Power module and Connector AC power conn...

Page 10: ...wer is off Green Lit when power module is in normal operation Status LED The Managed Switch status is indicated by the Status LED on the front panel of the device LED Color Operation Status Green Lit...

Page 11: ...ps port link is up Blinking when Fiber port is receiving and transmitting data at the speed of 1000Mbps TP F O 9 10 Port LEDs LED Media Type Color Operation Link ACT Speed TP OFF No connection exists...

Page 12: ...meters max 1000Base T UTP Cat 5e 100 meters max UTP Cat 5 100 meters max EIA TIA 568B 150 ohm STP 100 meters max 100BASE FX Multi mode fiber module 2km Single mode fiber module 1000BASE SX Multi mode...

Page 13: ...10 Managed Switch please follow the procedures listed below These procedures will be respectively described in detail in the following sections Installation Requirements Checking the Package Contents...

Page 14: ...ents Unpack the package carefully and check the package contents The package should contain the following items One set of the Managed Switch 19 inch rack mount kit 1x long mounting bracket and 2x reg...

Page 15: ...far from the device Visually inspect the power cord and see that it is secured to the AC power connector Make sure that there is proper heat dissipation from and adequate ventilation around the switch...

Page 16: ...o install one set of FOS 3110 in a single rack space you need the 19 inch rack mount kit supplied with the switch Just follow the procedures listed below for step by step instructions to install your...

Page 17: ...secure each bracket Step 4 Align the mounting holes in the brackets with the desired holes in the rack and insert screws through each bracket and into the rack Step 5 Then tighten the screws with the...

Page 18: ...o secure the bracket 1 4 On the right side of the switch attach one shaped fixed piece by inserting the screws provided in the FOS combine kit through this fixed piece and into the mounting holes in t...

Page 19: ...6 Tighten the screws with the screwdriver to secure each middle mount to the left side of the switch Step 3 Align the holes of the middle mount described in Step 1 on the left switch with the holes of...

Page 20: ...in the regular brackets on both sides the left side of the left switch and the right side of the right switch with the desired holes in the rack and insert the screws through each bracket and into th...

Page 21: ...the mounting holes on the most left side of the bracket you purchase 1 2 Insert the screws provided in the 19 inch rack mount bracket through this bracket and into the bracket mounting holes at the b...

Page 22: ...rack mount bracket with the desired holes in the rack and insert the screws through this bracket and into the rack Step 4 Tighten the screws with the screwdriver to secure this bracket with the switc...

Page 23: ...nt of power failure unplug the power that is plugged into the switch at the back of the device When power is resumed plug the power back to the switch 2 5 Connecting the Managed Switch to the Network...

Page 24: ...ement Local Console Management Users may connect a Terminal or PC running the Terminal Emulation program such as Putty or Tera Term with the following serial console port settings to the Managed Switc...

Page 25: ...Management Web Management is done over the network Once the Managed Switch is available on the network you can login and monitor the status of it through a web browser remotely or locally Local consol...

Page 26: ...1 Local Check Users can perform local check by observing LED indicators status or check system setup and configuration through console connection When the whole system fails to function 1 Check Power...

Page 27: ...ser serviceable parts DO NOT UNDER ANY CIRCUMSTANCES open and attempt to repair it Failure to observe this warning could result in personal injury or death from electrical shock Failure to observe the...

Page 28: ......

Page 29: ...18F 6 No 79 Sec 1 Xintai 5th Rd XiZhi Dist New Taipei City 221 Taiwan R O C Tel 886 2 2698 9661 Fax 886 2 2698 9662 Dir Line 886 2 2698 9201 www ctsystem com...

Reviews: