background image

EMI : FCC Class A, CE 

 

 

 

 
 
 

CVT-RACK-16

 

 

 
 

16 slots U niversal 

Medi a Converter Rack 

optional for AC power

 

 

 
 
 
 
 
 
 
 
 

 
 
 

 
 
 

 
 
 

User's  G ui de

 

 

Versio n1.9

 

Tr ad emarks 

Co p yrig ht  Connectio n Techn olo g y S yst em s Inc . 
Contents su bjec t to revis ion without prior notice. 
CT S is a registere d trade mark of Connectio n 
Technolog y S ystem s Inc ., 
Other tradem ark s rema in the p ro pe rt y of their 
owners . 

 

 

Copyrigh t S tatemen t

 

T his publicati o n m a y not be r ep r oduc e d as a whole 
or in part , in a n y wa y wh a t soever unless prior 
consent has be en obtained from Connectio n 
Technolog y S ystem s Inc . 

 

 

FCC Warni n g

 

T he CV T- R AC K-16 has b een tested and certif ied as 
with in Class A dig ita l sp e cific ations u nder Part 1 5 of 
FCC R u le s . Th e se st a n d a rds are d e sig n e d to pro vid e 
rea s o nab le pr otection  fro m ha rmf u l in terfe renc e whe n 
these un its  are  used in  a  co mm ercial e n viro n me nt. 
T hese de vices can  use,  generate an d  radiate rad io 
fre qu e nc y en erg y and ma y c au s e h a r mf u l interfac e to 
radio co mm un ica tio n s  un less in sta lle d in acc ordan ce 
w i t h   t h e   i n s t r u c t i o n s   i n   t h i s   U s e r ' s   G u i d e . 
Op eratio n of this de vice in a residential  area is likely 
to  cause  h a r mf ul  interf erence whic h  will  ma ke  the 
user  re sp on s ib le for the ap propria te re me di a l action 
at his/h er expense. 

 

 

CE Mark   Warning

 

T he  CVT-RAC K-1 6  is  a  Clas s  A  product .  In  s om e 
dom estic envir onm ent s it m a y caus e radio interf ac e 
in   whic h   cas e   the   user   will   need   to   consider 
adeq uat e preventat ive m eas ures . 

1. Intr odu c ti on

 

 

T h e   C T S   ( C o n n e c t i o n   Te c h n o l o g y   S ys t e m s ) 
M e d i a    C o n v e r t e r   R a c k ,   C V T - R A C K - 1 6   i s 
d e s i g n e d   t o   a c c o m m o d a t e   s i x t e e n   s e p a r a t e 
and  in de pen de n t   CT S   m ed ia  converters  within 
a rack -m ountab le r ack . 

 

 

T h e   C V T- R A C K - 1 6   i s   f i t t e d   w i t h   t w o   h o t - 
s wa p p a bl e   p o wer   s u p p lies   and       three   hot- 
s w a p p a b l e   f a n s   f o r   e n h a n c e d   r e l i a b i l i t y. 
T his  m eans  tha t  if  one  sup pl y  f ails ,  the  other  is 
capable  of   tak ing  over  im m e diate l y.  T he  other 
benef it  is  that  if  po wer  sup pl y  or  f an  f ails  th en  it 
can  be  replace d  wit h  a n other  on e  withou t  tak ing 
back whole CVT-RACK-16. 

 

 

Po wer   stat us   is   sh o wn   on   th e   L ED   di s p la y 
enabling   the   us er   to   m onit or   an d   respond   as 
n e c e s s a r y.   Fo r   o p t im al   p e r f o rm a n c e ,   p le a s e 
ensur e   th at   th e   C VT-RACK- 16   is   placed   in   a 
well-ventilate d  positio n,  enabling  air  to  circulat e 
above and b elo w the unit. 

 

 

T he   CVT-RAC K-1 6   c an   als o   be   installe d   in   a 
standar d   19-inc h  sit e   rack ;   provision  has  been 
m ade f or the ap pro priat e connectin g b rac kets . 

 

 

The  Med ia  Converter   R ac k  has  been  de sig ne d 
to  ho use  only  the  pr o p ri et a r y  range  of  m edia 
co nv e r te rs .  A ny   ot her   con fig ur atio n  is  at  the 
user s  own  ri sk.

 

 

 
 
 
 
 
 
 
 
 
 

 
 
 

 
 
 

2. Ins talla tio n 

(Refer to the back page) 

3. Spe ci fic a tion s  

Order  In form ation 

2. 1 Rac k  Moun tin g

 

T he  CVT-RACK- 16  can  be  m ount ed  in  a  stan d ar d 
EIA  19-inc h  rack .   Beg in  b y  aligning  the  m ounting 
brack ets  alon g  th e  sid es  of  the  unit  with  the  slit 
over  the  h oles .  Secur e  the  screws  tightl y  t o  f it  the 
brack ets   to   the   de vic e   bef or e   f ixing   it   into   the 
19-inc h   rack .   Pleas e   ens ur e   that   the   vent ilation 
h o l e s   a r e   n o t   o b s t r u c t e d .   T h e   s t e p   b y   s t e p 
pr oc ed ur e is shown next page . 

 

2. 2 Media  Converter

 

 

1. Scre w up per and lo wer sliders on m ed ia 

converter. 

2. Ca r ef ull y align t h e slid er an d slide wa y, then 

pres s  wit h firm and ste ad y pressure . 

 

2. 3 Cabli n g

 

 

1. T he correc t c ab le s pec ificatio n s and dis tances will 

be list ed in the m edia converter d oc um ent atio n . 

 

Slot  num ber 

16 slots 

 

LED 

Power A Activit y 
Power B Activit y 

 

Redu n da n cy 

2 Hot-s wappab le redundant Po wer s 

 

Power 

Slide-in  Po wer  Module: 
Input  AC  110 V,  50/60Hz 
or 220V, 50/60Hz 
50/60Hz 
Output DC 5V 
Power Cons um ptio n : 
Em pt y Loading : 9.5W 

 

Typical  Operation  &  Storage  Temperat ur e 

O pe r ation: 0  ~ 50

o

 

CVT-RACK-16 

16 Slots Unive rsa l Med ia Converter Cent er 

 

CVT-RACK-16-AC 

Slide in AC Po wer M od ule f or CVT-RACK-16 

 

CVT-RACK -16  FB 

Front Brack et set f or C VT-R AC K -16(O pti ona l) 

 

 

Strong l y Rec omm e n de d:

 

 

T o    e n s u r e   t h e   b e s t   p e r f o r m a n c e   o f 
sta n da lon e  m edia  c on v ert er s ,  pleas e  keep 
your   env ir on m en t    te mperatur e    under   40 
degrees   C elsius .   Or   ,   insta ll     two   pow er 
modules  for  CVT-R ACK -16.

 

2. Co nn ec t  inpu t  m ed ia cable to th e f ront of m edia 

converter. 

 

2. 4 Po werin g

 

 

1. Co nn ec t the f ema le en d of the po wer cor d to the 

MCR. 

2. Co nn ec t the m ale end of the po wer cord t o an 

externa l AC outlet . 

3. T he po wer A, B LED's on the CVT-RAC K-16 will 

illum inat e whe n the inst al latio n is do ne co rrectl y. 

4. Si m ilarl y, the po wer i n dicator LED's on th e m edia 

converter will illum inat e wh en in stallati o n is 
com plete an d correct. 

Storage Tem perature : -20  ~ 60

o

Hum idit y:5 % ~ 90% non - con de nsi n g 

 

Dimension  and  W eig ht 

Size : 44 0 x 385 x 88 mm (W xDxH) 
Shipping W eight: 
CV T-R AC K-16(Rack Only): 7.85 K G 
CV T-R AC K-16(With 2 Power Module): 10.8 K G 

 

E mi ssi o n/Sa fety: 

Contact  Inf or mati o n: 

C o nn ectio n Te c hn o lo g y Syst em s  INC (CT S) 
18F- 6, No.7 9, Sec. 1, Xintai  5th Rd., Xizh i  Dis t., 
Ne w Taipei  Cit y  22 1, TAIW AN, R.O.C. 
T EL: +8 86 2 26 98 966 1  FAX : +886 2 26 989 662 
E-Mail:  inf o @ c t s yst e m . c o m 