www.ctronicssecuritycameras.com
11
a
、
Press the key
“
set preset
”
, Then make the camera moved to the need position
by shaking joystick.
b
、
Enter
“
83
”
c
、
Press the key
“
enter
”
d
、
Make the dome rotating to the left position of left limit position
e
、
Enter
“
84
”
f
、
Press the key
“
enter
”
(
2
)
Calling Limit scanning
By controlling keyboard or DVR to implement the command “call No.91 preset
position” dome will perform start limit scanning. The other limit scanning set or call
is shown in Table 7.
Table 7
:
Limit scanning and preset relation table
Limit scanning
setting
calling
the first scan
Left limit
:
set No.83 preset
Right limit
:
set No.84 preset
Call No.91 preset
the second scan
Left limit
:
set No.85preset
Right limit
:
set No.86preset
Call No.92 preset
the third scan
Left limit
:
set No.87 preset
Right limit
:
set No.88 preset
Call No.93 preset
(3)
355
°
Horizontal scanning
By controlling keyboard or DVR to implement the command “call No.99 preset
position” dome will perform start 355
°
Horizontal scanning.
(4)
pattern scan
This product has 4 groups of pattern scan.Pattern Scan refers to the scanning
motion ball machine between two points by irregular trajectory has been set to
perform reciprocating scanning.
About pattern scan corresponding setting and calling show in the table 8.
Example
:
Use a type of control keyboard for the first group pattern scan settings
or calling.