IP address 

 

Normally the IP address will be found by interrogating the router. If this is not 

possible you can download this program which will tell you the IP address: 

  

https://www.lantronix.com/products/deviceinstaller/

 

  

Install the program, run it and it will auto search. If not just press search. 

  

If you want to fix the IP address double click on the name it found (XPort-NN)  

Then select web configuration, then press the right green arrow. 

When it asks user name and password just click ok. 

Select network and you will see configuration settings. Select ‘use the following IP 

configuration’. 

Type in your required IP address and mask. 

Select OK at the bottom of the page. 
Select apply settings on the left. It will take a minute or so to save the settings and 

will tell you when it’s done. 

Power cycle the unit and it will use the IP address you typed in. 

  

Be careful about some of the other settings you can access, there are many of them 

that can stop the unit operating correctly. 

 

 

Updating 

 

When firmware updates are available, they may be downloaded from: 

 

https://www.ctpsystems.co.uk/support.html 

 

and programmed using our firmware update manager available on the same page. 

Full instructions will be supplied with the update. 

 

 

Audio Outputs 

 

Audio outputs are available as analogue, AES and embedded. 

 

Connect a video SDI/HD-SDI source to SDI In. The unit will embed the four audio 

channels to channels 1-4 respectively of the SDI signal. Any other audio embedded 

channels will just pass through. Connect to SDI Out for your embedded signal. 

 

The four analogue outputs are available on the D25 connector on the rear as are the 

AES audio signals. The AES sample rate is 48kHz. 

Summary of Contents for RMA400

Page 1: ...RMA400 Quad Embedding Ethernet Controlled Microphone Amplifier by CTP Systems ...

Page 2: ...ty EN55035 2017 WEEE CTP Systems are registered for Business to Business sales of WEEE in the UK Our registration number is WEE DF0509VR This is why our product has a ridiculous picture of a dustbin on the back RoHS The product conforms to the RoHS Directive 2002 95 EC for restriction of the use of hazardous substances in electrical and electronic equipment This unit was designed and manufactured ...

Page 3: ...ing any other button will show Locked on the display Press the two centre HPF buttons for approximately 3 seconds and the unit will display Unlocked Settings may now be changed as required A single press on the Mon Sel button will display the gain and limiter settings for that channel Press the button again and Micx will be highlighted Now press the and buttons to adjust gain as required Gain rang...

Page 4: ...nit to your network insert the unit s IP address into the box leave the port number as 10001 and press connect The status display will change to Connected If it doesn t please check your IP address and connection On connection the software will automatically upload the RMA400s current status The software is now live any changes made will be automatically downloaded to the RMA400 The displays and s...

Page 5: ...o save the settings and will tell you when it s done Power cycle the unit and it will use the IP address you typed in Be careful about some of the other settings you can access there are many of them that can stop the unit operating correctly Updating When firmware updates are available they may be downloaded from https www ctpsystems co uk support html and programmed using our firmware update man...

Page 6: ...tted to unit Hot Cold Screen Function 24 12 25 Analogue output 1 10 23 11 Analogue output 2 21 9 22 Analogue output 3 7 20 8 Analogue output 4 15 3 16 AES outputs 1 2 1 14 2 AES outputs 3 4 These connections closely resemble the Tascam standard ...

Reviews: