Ground Wire Requirements
Table 3-D provides the recommended gauge for ground wire based on the
distance between the CTPhone Controller and the master grounds bus on
the office telephone system. The proper gauge wire ensures that DC resis-
tance does not exceed 0.25 ohms.
CTPhone Controller Indicators
For information on CTPhone Controller LEDs, see the Diagnostics and
Troubleshooting chapter.
Adding Analog Line Modules to the CTPhone Controller
The CTPhone Controller supports a maximum of 8, 16, 24, or 32 CTPhone
handset users, depending on its configuration. You may add groups of 8
users to a CTPhone Controller configured for less than 32 users by install-
ing an Analog Line Module (ALM) in the CTPhone Controller.
Caution When unplugging an Analog Line Module, unplug the card from
connectors J4, J5, or J6 first before disconnecting it from the standoffs. Do
not apply diagonal pressure to the DIN connectors (see Figure 3-11 on
page 3-16).
Table 3-D. Ground Wire Requirements
Distance Between CTPhone Controller and
Master Ground Bus
Recommended
Gauge
0 – 18 feet
16 AWG
0 – 30 feet
14 AWG
0 – 46 feet
12 AWG
0 – 73 feet
10 AWG
0 – 113 feet
8 AWG
+
Installing an Analog Line Module in the CTPhone Controller
Step
Procedure
1
Power down the CTPhone Controller.
2
Remove the screws securing the cover of the CTPhone Con-
troller case and lift the cover.
Summary of Contents for CTPhone 1900
Page 1: ...DOC00101 01 5 97 CTPhone 1900 System application manual...
Page 2: ......
Page 3: ...ctphone 1900 system application manual...
Page 10: ......
Page 12: ......
Page 87: ...DOC00101 01 4 13 CTPhone 1900 System Configuration...
Page 88: ......
Page 108: ......
Page 117: ...DOC00101 01 6 9 CTPhone 1900 System Specifications...
Page 118: ......
Page 124: ......
Page 130: ......
Page 131: ......
Page 132: ...Printed in USA...