background image

8

Pairing of Sensor and Cooker Guard Relay 

The Mkomfy set with sensor and cooker guard relay in the same pack are 
already paired. If you have bought a separate sensor, this must be paired 
with the cooker guard relay. This can be done in two different ways. 

Read through the whole instruction for both alternatives before performing pairing!

Alternative 1: 

Pairing of Sensor without physical intervention on cooker guard relay.

1. 

Activate Sensor in pairing mode by setting DipSW 4 to active [ON]. 

2. 

Disconnect the power to the cooker guard relay for 5 seconds by 
turning the relevant fuse circuit off and on.  
- Within 20 seconds of turning the fuse circuit on:  
 

Hold in the function button on the sensor for 6 seconds.  

The sensor will emit a sound signal every 2 seconds, if pairing 
has succeeded.

3. 

Once again, disconnect the power to the cooker guard relay 
for 5 seconds by turning the relevant fuse circuit off and on. 

 

NB! This must be done within one minute of connecting the 

relay under Point 2, or the pairing will not be saved

4. 

Set DipSW 4 back to inactive [OFF].

  

Pairing is now complete.

Alternative 2: 

Pairing of Sensor by activation of programming button on cooker guard relay.

1. 

Activate Sensor in pairing mode by setting DipSW 4 to active [ON].

2. 

Briefly press the programming button on the cooker guard relay. 
Yellow diode will now begin to flash. The cooker guard relay will 
now be in pairing mode for 30 seconds. 

3. 

Hold in the function button on the sensor for 6 seconds while 
the yellow LED flashes. The sensor will emit a sound signal every 
2 seconds, if pairing has succeeded. 

4. 

Set DipSW 4 back to inactive [OFF].

NB: It is not possible to have more than 1 Mkomfy Sensor connected to the 
Cooker Guard Relay at the same time. Pairing a new sensor will automatically 
delete the sensor already paired with the cooker guard relay. 

Installation information

Summary of Contents for Mkomfy R-T 25A

Page 1: ...structions User instructions Mkomfy R T 25A SAVE THESE INSTRUCTIONS Panel installed cooker guard relay Mkomfy set with sensor and relay is supplied ready paired and ready for use Fulfilstherequirement...

Page 2: ...ensor is removed from its bracket a safety function is activated which cuts off the power to the cooker On activation the sensor will beep once a second for 5 seconds before disconnecting the cooker T...

Page 3: ...he timer function can be temporarily changed from 2 hours operating time to 12 hours operating time This is done by pressing the function button for 10 seconds The sensor acknowledges this with two so...

Page 4: ...en necessary This is done by 2 short sound signals every 5 minutes 1 Flip the cooker guard away from the wall 2 Loosen two screws on the rear and remove the cover 3 The batteries can then be turned ou...

Page 5: ...ke sure it is dry before pressing the cooker guard into place at the correct height remove the backing tape The adhesive foot must be fixed to the cooker guard Installation information 40 to 50 cm 30...

Page 6: ...and set slide switch 4 to position ON Slide switch 2 Point the sensor eye marked towards your own face forehead and check that the cooker turns off the temperature of your forehead is over 30 C Sensor...

Page 7: ...r 20 seconds in the event of overheating rather than the standard 40 seconds Extra high temperature To be carried out only by an authorised installer In certain locations or with certain types of hob...

Page 8: ...the cooker guard relay for 5 seconds by turning the relevant fuse circuit off and on NB This must be done within one minute of connecting the relay under Point 2 or the pairing will not be saved 4 Set...

Page 9: ...ected Flashes if there is no communication with the sensor Red Flashes when paired units are deleted or if the command from the sensor is rejected Yellow Flashes when the relay is set to pairing mode...

Page 10: ...h a sound signal and red flash R T 25A Prog N N L L IN LOAD CONTACTOR Can also control a contactor This is recommended when the RC circuit is mounted in parallel with the coil on the contactor Install...

Page 11: ...minutes NB Make sure you have new batteries to hand Alarm signal Three 3 sound signals every 5 seconds lasting for 40 seconds and the LED flashes Cause Overheating Action Press the button and take ac...

Page 12: ...Tel 47 72831611 El No Name 6251698 Mkomfy R T 25A Technical data Mkomfy Komfyrvakt R T 25A Voltage 230 VAC 10 Max load 25 A Physical dimensions sensor 96x66x28 mm Timer 2 hours 12 hours Battery type...

Reviews: