SAFELY INSTRUCTIONS : 

 

This fine product that you have just purchased is constructed from the highest quality 

materials and workmanship.  

 

Before installation and operation, we recommend the following procedures: 

  

 

CHECK WITH YOUR LOCAL ELECTRICAL AUTHORITY TO ENSURE YOU COMPLY WITH LOCAL 

ELECTRICAL REGULATIONS. THESE ELECTRICAL CODES HAVE BEEN DESIGNED FOR YOUR SAFTY.   
BE SURE TO COMPLY WITH THESE CODES.  

 

B

 

WE RECOMMEND THAT A SEPARATE AND DEDICATED CIRCUIT BE PROVIDED FROM YOUR HOME 

ELETRICAL DISTRIBUTION PANEL.  IT SHOULD BE PROPERLY PROTECTED WITH EITHER A FUSE OR A 
CIRCUIT BREAKER.  

A GROUND FAULT CIRCUIT INTERRUPTER (GFCI) IS MADATORY

.  CONSULT A 

LICENSED ELECTRICIAN FOR ALL WIRING. 

C

 

THE GROUND TERMINAL ON THE THREE PRONG PLUG SHOULD NEVER BE REMOVED.  THEY ARE 
SUPPLIED AND DESIGNED FOR YOUR PROTECTION. 

 

D

 

NEVRE MAKE ADJUSTMENTS TO ANY ELECRRICAL APPLIANCE OR PRODUCT WITH THE POWER 

CONNECTED.  BE SURE TO UNSCREW THE FUSE OR TRIP THE BBREAKER TO THE OFF POSITION AND 
REMOVE THE POWER PLUG FROM THE RECEPTACLE BEFORE PROCEEDING   

 

 

 

 

 

The necessary tools for the installation are: 

-

 

One (1) electric reciprocal saw or one de 6¼’’ (160 mm) hole saw 

-

 

One (1)  electric drill with a 1¼’’ (32 mm) diameter drill bit 

-

 

One (1) Robertson or Philip screwdriver 

-

 

White (1)  weather sea caulking for around the outside vent  

 

 

 
 

 

Preparation 

Summary of Contents for DLW120

Page 1: ...Support Call 1 866 231 8893 or email info ctm inter com Kindly provide the model place and date of purchase and a short description of the problems CENTRE DE SERVICE A LA CLIENTELE CONSERVEZ CE MANUA...

Page 2: ...ECTED WITH EITHER A FUSE OR A CIRCUIT BREAKER A GROUND FAULT CIRCUIT INTERRUPTER GFCI IS MADATORY CONSULT A LICENSED ELECTRICIAN FOR ALL WIRING C THE GROUND TERMINAL ON THE THREE PRONG PLUG SHOULD NEV...

Page 3: ...igh heat source such as furnaces boilers radiators baseboard heaters or any similar heat source Avoid placing the unit beneath a bedroom as the noise of the fan motor may disturb some people Select th...

Page 4: ...centre guide drill a 6 160 mm hole from the outside to the inside of the house to allow the passage of the evacuation pipe STEP 2 STEP 3 STEP 4 Using the provided screws and anchors fix the long suppo...

Page 5: ...of the lower suction tunnel pieces Place the upper suction tunnel piece above the lower suction tunnel piece The screws at the bottom of the upper suction tunnel also secure the top of the lower suct...

Page 6: ...alize the installation of the outside vent It may be necessary to make several longitudinal cuts to the pipe end to secure the outside vent Apply the white weather seal caulking between the outside ve...

Page 7: ...at 46 or more high speed Winter Relative humidity at 55 or less low speed Relative humidity at 56 or more high speed It is possible to override the seasonal settings To keep the system at high speed p...

Page 8: ...e plastic bulkhead to the position shown in the picture And change the direction of the top cover Using the screws re install the top cover In this configuration the distance between the celling and t...

Page 9: ...003 Fan Casing 2 pieces CSJ23004 Control Panel CSJ23005 Circuit Board support 4 CSJ23006 Circuit boards CSJ23007 Relative humidity sensor kit CSJ23008 Electric cord strain relief CSJ23009 Electric cor...

Page 10: ...OU UN DISJONCTEUR DE CIRCUIT UN DISJONCTEUR DE FUITE DE TERRE DFT EST OBLIGATOIRE VEUILLEZ CONSULTER UN LECTRICIEN AGR POUR LE C BLAGE C LA PRISE DE TERRE SUR LA FICHE MOUL E TROIS BORNES NE DEVRAIT J...

Page 11: ...teur des plinthes chauffantes ou une source de chaleur semblable viter d installer l appareil au dessous d une chambre coucher puisque le bruit du moteur de la ventilation risque de d ranger les gens...

Page 12: ...al percez un trou de 6 160 mm de l ext rieur vers l int rieur du b timent pour permettre le passage du conduit d vacuation TAPE 2 TAPE 3 TAPE 4 En utilisant les vis et les ancrages fournis fixez le lo...

Page 13: ...tion Placez la pi ce sup rieure du tunnel d aspiration au dessus de la pi ce inf rieure du tunnel d aspiration Les vis au bas de la partie sup rieure du tunnel d aspiration consolident galement le hau...

Page 14: ...l installation de l vent ext rieur Il pourrait tre n cessaire de faire des incisions longitudinales vers le bout du conduit afin de fixer l vent ext rieur Appliquez le calfeutrage tanche blanc entre...

Page 15: ...faible vitesse Humidit relative 56 ou plus haute vitesse Il est possible de neutraliser les r glages saisonniers Afin de garder le syst me une haute vitesse appuyez sur la touche de droite Afin de gar...

Page 16: ...plastique dans la position montr e sur l image Modifiez l orientation du couvercle sup rieur En utilisant les vis r installez le couvercle sup rieur Dans cette configuration la distance entre le plafo...

Page 17: ...nneau de commande CSJ23005 Support de carte de circuits 4 CSJ23006 Carte de circuits CSJ23007 Ensemble de capteur d humidit relative CSJ23008 Serre c ble du cordon lectrique CSJ23009 Cordon lectrique...

Reviews: