background image

Start charging

1. Once you have checked that the battery leads have been connected correctly, you can start 
charging by connecting the charger to the wall socket. If the battery leads have been connected 
incorrectly the polarity reversing protection will ensure that neither the charger nor the battery 
will be damaged. The fault indicating lamp 

 will then come on. If this is the case, start from 

point 1 under ”Connecting the charger...” 
2. The charging lamp 

 or the maintenance charging lamp 

 will now come on. When the 

maintenance charging lamp comes on the battery is fully charged. When the battery’s voltage 
drops the charger will send a pulse to the battery. The pulse length depends on how much the 
voltage has dropped. The charger can be connected for months.
3. If nothing happens. If none of the lamps come on this may be due to the connection to the 
battery or chassis is poor or that the battery is faulty or has a too low terminal voltage. Another 
cause may be a lack of voltage in the wall socket..
4. Charging can be stopped at any time by disconnecting the charger’s power cord. Always 
disconnect the power cord before disconnecting the battery leads. When you stop charging a 

EDWWHU\¿WWHGLQDYHKLFOH\RXVKRXOGDOZD\VGLVFRQQHFWWKHEDWWHU\OHDGIURPWKHFKDVVLVEHIRUH

you disconnect the other battery lead.

,IWKHFKDUJLQJODPSDQGPDLQWHQDQFHFKDUJLQJODPSDOWHUQDWHO\ÀDVKWKHUHDVRQIRUWKLVLV

the following:

,IWKHODPSVÀDVKDIHZWLPHVSHUVHFRQGWKHQWKHEDWWHU\LVSUREDEO\VXOSKDWHG,IWKHODPS
ÀDVKHVPRUHWKDQPLQXWHVWKHEDWWHU\VKRXOGEHUHSODFHG
,IWKHÀDVKLQJRFFXUVZLWKDIHZPLQXWHVLQWHUYDOWKHQWKHEDWWHU\KDVDKLJKVHOIGLVFKDUJH

and may need to be replaced.

CHARGING PHASES 

CTEK XC 800 has a four step fully automatic charging cycle IUoUp. At the start of charging 
the battery charger delivers maximum current to the battery and the battery voltage increases 
constantly to a set level of 7.2V. At this point the voltage will be regulated and kept constant 
while the charging current is successively lowered. Once the charging current has dropped 
below 0.4A the charger switches to maintenance charging.
If the battery is loaded and the battery’s terminal voltage drops to 6.45V the charger automati-
cally switches back to the beginning of the four step cycle. The charger requires a reverse 
voltage from the battery of at least 3.7V to start the charging cycle, this means that if the battery 
is so deeply discharged that the terminal voltage is lower than 3.7V the charger cannot charge 
the battery in question. A normal discharged battery has a terminal voltage of 5.3V.

Summary of Contents for XC 800

Page 1: ...CTEK XC 800 Battery charger For lead acid batteries 1 2 100Ah User Manual and guide to professional battery charging for Starter and Deep Cycle batteries GB ...

Page 2: ... into contact with water Never charge a frozen battery Never charge a damaged battery Do not place the charger on the battery while charging The electrical connection must fulfil the national heavy current requirements Check the cabling in the charger before use Make sure there are no cracks in the cabling or in the protective covering A charger with damaged cables may not be used Always check tha...

Page 3: ...ively grounded battery Connect the black wire to the negative pole of the battery and the red cable to the vehicle s chassis Be careful not to connect the red cable in the vicinity of a fuel pipe or the battery Charging of a battery not connected to a vehicle 1 The power cord should be disconnected before connecting or disconnecting the battery leads 2 Connect the red wire to the positive pole of ...

Page 4: ...YHKLFOH RX VKRXOG DOZD V GLVFRQQHFW WKH EDWWHU OHDG IURP WKH FKDVVLV EHIRUH you disconnect the other battery lead I WKH FKDUJLQJ ODPS DQG PDLQWHQDQFH FKDUJLQJ ODPS DOWHUQDWHO ÀDVK WKH UHDVRQ IRU WKLV LV the following I WKH ODPSV ÀDVK D IHZ WLPHV SHU VHFRQG WKHQ WKH EDWWHU LV SUREDEO VXOSKDWHG I WKH ODPS ÀDVKHV PRUH WKDQ PLQXWHV WKH EDWWHU VKRXOG EH UHSODFHG I WKH ÀDVKLQJ RFFXUV ZLWK D IHZ PLQXWHV ...

Page 5: ...een 95 and 100 The battery receives a pulse when the voltage drops Keeps the battery in perfect condition when it is not used The charger can be connected for months at a time If possible check the water level in the battery TEMPERATURE PROTECTION CTEK XC 800 is protected from being overheated The power will be reduced if the ambient temperature is raised MAINTENANCE The charger is maintenance fre...

Page 6: ... SPECIFICATION Voltage AC 170 260VAC 50 60Hz Back current drain 1Ah month Voltage Charging Voltage Nominal 6V 7 2V Ripple Max 10mV rms max 12mA Current 0 8A max Ambient Temperature 20 C to 50 C power is reduced automatically at increased ambient temperature Cooling Natural convection Charging cycle CTEK XC 800 is a multistage fully automatic charger Type of batteries All types of 6V lead acid batt...

Page 7: ...following EMC standards EN 55011 EN 61000 3 3 EN 61000 3 2 EN 55014 1 and EN 55014 2 according to the terms of directive 89 336 EEC with the addition of 92 31 EEC and 93 68 EEC The charger comes in different models with different types of electrical plugs The charger with WKH ÀDW HXURFRQWDFW LV LQWHQGHG IRU 6ZLW HUODQG VIKMANSHYTTAN SWEDEN 2006 01 23 Börje Maleus VD CTEK SWEDEN AB Rostugnsvägen 3 ...

Reviews: