CHARGING CYCLE
Setting: 14.4 V or 14.7 V
MULTI XS 7000 performs a 5-step fully automatic charge cycle,
IIUoIUp. Lamp B for 14.4 V or Lamp C for 14.7 V.
Start:
Starting phase for charging. The current is restricted to 3 A.
It ends when the voltage is above 10.5 V. There is a time-out after
6 hours and the charger switches to Error indication, (lamp 0). This
indicates a faulty battery or an undersized charger for the battery
pack. Lamp 1 indicates this phase.
Bulk:
Main part of the charge cycle when about 80% of the charge
is returned. The charge is carried out at maximum charge until full
voltage is achieved. Lamp 2 indicates this phase.
Absorption:
Final part of the charge. The voltage is kept constant
until the current has dropped to a very low level. The phase is also
ended if the total time for bulk and absorption exceeds 40 hours. Lamp
3 indicates this phase.
Pulse Maintenance charge:
The state of charge is between 95% and
100%. A pulse at 5 A is sent out if the voltage drops. This gives mini-
mum water loss and maximum life. The charger could be connected
for years without problems. The charger measures the voltage every
10 minutes to decide whether a new pulse should come. This means
that these pulses can’t come more often than every 10 minutes.
If the battery is charged and/or the battery's terminal voltage drops
below 12.7 V (Mode 14.4 V) or 12.9 V (Mode 14.7 V), the charger
starts a charge pulse of 5A until the terminal voltage has reached the
set level, 14.4 V or 14.7 V. The charge pulse is then interrupted and
the cycle is repeated as long as the charger is in pulse maintenance
phase. Pulse maintenance phase is indicated by lamp 4.
If the terminal voltage drops below 12.1 V, the charger automatically
reverts to the beginning of the charging curve.
Setting : Supply 13.6 V
MULTI XS 7000 has a Supply mode setting which has a constant volt-
age at 13.6 V and current up to 7 A. It could be used for maintenance
charge using the Float approach. This approach keeps the battery
at 100 % State of Charge, but the constant small overcharge also
increases water loss. Note that there is no need for a battery to be
connected at this mode. Note that the Spark Free function and the
indication of Reverse Polarity is suppressed in this mode. The protec-
tion is still working.
It is not advisable to charge a discharged battery in Supply mode as
this will not provide a complete charge.
In this mode, MULTI XS 7000 can also be used as a power-generation
unit for operating equipment that requires 13.6 V and a maximum of
7 A. If the selected current exceeds 7 A, the output voltage will drop at
an increasing rate. The charger has electronic overload protection in
this mode, which is activated if the charge is so great that the output
voltage from the charger falls below around 3.5 V and the current to
around 7 A. In the event of an overload, the charger transfers to error
mode (lamp 0).
Setting lamp D indication lamp 5.
Setting: Boost 16 V / 1.5 A / 4 h
MULTI XS 7000 has a Boost-setting which gives a constant current
at 1.5 A, maximised at 16 V for 4 hours. It will automatically go over
to 14.4 V pulse setting after a completed cycle. This mode is used for
batteries that have been deep discharged. Start by charging at either
the 14.4 V or 14.7 V setting until the battery is in Pulse maintenance
phase. Setting lamp E indication lamp 6.
BULK CHARGING TIME
TEMPERATURE PROTECTION
The charger is internally protected from being overheated. The power
will be reduced if the ambient temperature is increased.
MAINTENANCE
A MULTI XS 7000 doesn’t need any specifi c maintenance. Observe
that disassembly of the charger is not allowed and will void the
warranty.
A defective power cord has to be replaced. Keep your charger clean.
It could be wiped of with a soft tissue, after disconnecting the power
supply.
EQUIPMENT
MULTI XS 7000 is delivered with a set of battery leads with battery
pole clamps.
LIMITED WARRANTY
CTEK SWEDEN AB, Rostugnsv. 3, SE-776 70 VIKMANSHYTTAN,
SWEDEN makes this limited warranty to the original purchaser of this
product. This limited warranty is not transferable. CTEK SWEDEN
AB warrants this unit for two years from date of purchase against
defect workmanship or material. It is the obligation of the purchaser to
forward the unit together with proof of purchase to the manufacturer
or its representative with transportation cost prepaid. This warranty is
void if the unit is abused, handled carelessly or repaired by anyone
other than CTEK SWEDEN AB or its authorized representative. CTEK
SWEDEN AB makes no warranty other than this limited warranty and
expressly excludes any implied warranty including any warranty for
consequential damages. This is the only expressed limited warranty
and CTEK SWEDEN AB neither assumes nor authorizes anyone to
assume or make any other obligation towards the product other than
his limited warranty.
1
2
3
4
5
6
0
A
B
C
D
E
SPECIFICATION
Voltage AC
220-240 VAC, 50-60 Hz. Output power is
reduced at lower input voltage. A perfect
charge will still be achieved.
Current
0.9 A rms
Inrush Current
< 40 A
Back Current Drain*
< 3 mA
Charging Voltage
Nominal: 12 V
13.6 V, 14.4 V, 14.7 V or 16 V
Ripple**
Max 150 mV rms, max 0.3 A
Charging Current
7 A max
Ambient Temperature
- 20°C till + 50°C. Automatic reduction of
power at increased ambient temperature.
Cooling
Natural convention
Charge cycle
5 step fully automatic IIUoIUp.
Type of batteries
All types of lead-acid batteries
(Wet, MF, VRLA, AGM and GEL)
Battery Capacity
14-225 Ah
Dimensions
191 x 89 x 48 mm (L x W x H)
Insulation
IP 65
Weight
0.8 kg
*) Back Current Drain is what drains the battery if the charger is con-
nected without the power cord connected.
**) Quality of the current and voltage is very important. High current
ripple heats up the battery and makes the positive electrode age pre-
maturely. High voltage ripple could harm other equipment connected
to the battery. MULTI XS 7000 produces a high quality current and
voltage with very low ripple.
DECLARATION OF CONFORMITY
Manufacturer: CTEK SWEDEN AB, Rostugnsvägen 3, SE-776 70
VIKMANSHYTTAN, SWEDEN, Declares under sole responsibility
that the battery charger MULTI XS 7000, to which this declaration
relates is in conformity with the following standards: EN60335-1, EN
60335-2-29 following the provisions of directive 73/23/EEC amended
by 93/68/EEC and EN 55014-1, EN 61000-3-3, EN 610002/03/00, EN
55014-2 following the provisions of directive 89/336/EEC amended by
92/31/EEC and 93/68/EEC.
VIKMANSHYTTAN, SWEDEN, 10/10/02
Börje Maleus, Managing Director, CTEK SWEDEN AB
CTEK SWEDEN AB,
Rostugnsvägen 3
SE-776 70 VIKMANSHYTTAN
SWEDEN
Fax: +46 225 30793
www.ctek.se
INDICATIONS
Indication Description
0
Error mode, the charger interrupts the
charging/voltage supply. See description below.
1
Start mode, restricted charging current and battery
voltage under 10.5 V.
2
Bulk charging, Maximum charging current.
3
Absorption charging, Voltage restrictions to selected
voltage.
4
Pulse maintenance charging.
5
Supply mode, fi xed output voltage, no counter
voltage requirements.
6
Boost charging in progress, constant current 1.5 A.
Error mode
The charger goes to error mode in the following situations:
1.
Charging is started without a battery with terminal
voltage over 1.5 V being connected to the terminals.
2.
The battery is connected with poles reversed to the
charger's terminals.
3.
The terminals on the charger are short-circuited
when charging has started.
4.
The charger is overloaded in Supply mode.
5.
The charger has been in start mode for more than 6
hours.
6.
If the total time for bulk and absorption exceeds
40 hours.
Error mode is acknowledged/reset by pressing ”the MODE” button.
The charger restarts in the latest selected mode.
Battery size
(Ah)
Time to ~80% charge
(h)
20
3
75
10
115
16
225
32
002