CTEK MULTI XS 4003 1035 User Manual Download Page 7

7

EN

If the battery leads are incorrectly connected, the reverse polarity protection will 

ensure that the battery and charger are not damaged. 

Start charging

1. When you are sure the battery leads are correctly placed, connect the charger 

to the wall socket. The charger will indicate that the mains voltage is connected. 

If the battery leads are incorrectly connected, the reverse polarity protection will 

ensure that the battery and charger are not damaged. The fault indicator lamp will 

be lit. If this is the case start from section 1 again “Connection of charger...”. 

2. In order to start charging the correct current and voltage must be set by pressing 

the “MODE” button until the proper setting is lit. Selecting the setting for your 

battery is described in “BATTERY TYPES AND SETTINGS”. 

3. The lamp for deeply discharged battery will indicate if the battery voltage is low 

(see Min battery voltage in “TECHNICAL SPECIFICATIONS”).

4. 

Normal charging will be indicated by the lamps for soft start (deeply discharged 

battery) bulk charge, absorption charge or maintenance charge. When the 

lamp for maintenance charge is lit this means that the battery is fully charged. 

The charge will restart again if the voltage drops. Indications for Recond and 

Snowflake modes are described in “BATTERY TYPES AND SETTINGS”.

5. If the lamp that indicates settings and the power lamp remains lit but no other lamp 

is lit, there could be a bad connection to the battery or chassis or the battery could 

be defect or have a terminal voltage that is too low. The charger requires that the 

battery voltage is above a certain level, see “TECHNICAL SPECIFICATIONS” 

to start the charging cycle. This means that if the battery is in a state of deep 

discharge the charger will be unable to charge the battery in question. Another 

reason could be lack of power from the wall socket. Start by improving the 

connection between the battery and the charger.

6. Charging can be stopped at any time by disconnecting the mains cable from 

the wall socket. Always disconnect the mains cable from the wall socket before 

disconnecting the battery leads. When you interrupt charging of a battery installed 

in a vehicle, you must always disconnect the battery lead from the chassis before 

disconnecting the other battery lead. 

CHARGING STEPS

All battery chargers charge and analyse in eight fully-automatic steps.  

The MULTI XS 4003 model has many different settings, see “BATTERY TYPES AND 

SETTINGS”. 

The battery chargers have an 8 step fully-automatic charging 

cycle:

Desulphation

Desulphation with pulses restores sulphated batteries. This is indicated with a fixed 

beam during this step.
Soft start 

Starting mode for charging cycle. The start step continues until the battery terminal 

voltage has risen above the set value, at which time the charging switches to bulk 

charge. If the terminal voltage has not reached the set level within a set time, the 

charge is stopped and the charger indicates error mode. The battery is then probably 

defective or too large. 
Bulk

Main charge until 80% of the charge is complete. The charge is carried out at 

maximum current charge until the terminal voltage reaches the set level. Bulk 

charging has a maximum time. The charging then switches to Absorption. 
Absorption

Final part of the charge up to 100%. During this step the charge current falls 

gradually to ensure the terminal voltage does not get too high. If the maximum time 

for Absorption is exceeded, the charger switches automatically to maintenance. 

Summary of Contents for MULTI XS 4003 1035

Page 1: ...I XS 4003 Battery charger For lead acid batteries 1 2 140Ah User s Manual and a guide to professional battery charging for starter deep cycle batteries Model 1035 QUICK GUIDE EN DE FR ES IT NL SE DK N...

Page 2: ...d to the positive pole of the battery and the black lead to the negative pole QUICK GUIDE MULTI XS 4003 When you are sure the battery leads are correctly placed connect the charger to the wall socket...

Page 3: ...ged Ready to use Snowflake Battery size 14 140Ah Recond Battery size 14 140Ah Settings are made by pressing the MODE button and stepping forward one press at a time until the required mode is reached...

Page 4: ...s supply must be in accordance with the national regulations for electrical installations Check the charger cables prior to use Ensure that no cracks have occurred in the cables or in the bend protect...

Page 5: ...e for wet batteries MF and for most GEL batteries 14 140 Mode 14 7V 4A This mode is recommended for charging batteries at temperatures lower than 5 C It is also recommended for many AGM batteries This...

Page 6: ...batteries that are fitted in vehicles 1 The mains cable should not be connected to the wall socket when connecting or disconnecting the battery leads 2 Identify the pole that is earthed connected to c...

Page 7: ...arging cycle This means that if the battery is in a state of deep discharge the charger will be unable to charge the battery in question Another reason could be lack of power from the wall socket Star...

Page 8: ...that you have chosen the Recond Maintenance charge Float Charging with constant voltage Maintenance charge Pulse The state of charge varies between 95 and 100 The battery receives a pulse when the vol...

Page 9: ...Vp p and 160mAp p Ambient temperature 20 C to 50 C output power is reduced automatically at high temperatures Cooling Natural convection Charger type Eight step fully automatic charging cycle Battery...

Page 10: ...ests the state of the battery Main charge Top charge and minimal fluid loss YES 4A for max 8h until the voltage reaches 12 6V 4A for max 20h A combination of current limits and timers max 10h YES 0 8A...

Page 11: ...9V max voltage 14 4V Note In snowflake mode MULTI XS 4003 follows the same program as CAR but with a higher voltage 14 7V The product is protected by the following Patents EP1618643 SE525604 US754177...

Page 12: ...n those mentioned above i e no consequential damages Moreover CTEK SWEDEN AB is not obligated to any other warranty other than this warranty DECLARATION OF COMPLIANCE CTEK SWEDEN AB Rostugnsv gen 3 SE...