EN  •  3

supervision or instruction concerning use of the appliance by a person 

responsible for their safety. Children should be supervised to ensure that 

they do not play with the appliance.

 

(EN 7.12)

 This appliance can be used by children aged from 8 years 

and above and persons with reduced physical, sensory or mental ca-

pabilities, or lack of experience and knowledge if they have been given 

supervision or instruction concerning use of the appliance in a safe way 

and understand the hazards involved. Children shall not play with the 

appliance. Cleaning and user maintenance shall not be made by chil-

dren without supervision.

CHARGING

Connecting the charger to a battery fitted in a vehicle

1

. The power cord should be disconnected when connecting or disconnecting the battery leads.

2

. Identify the battery terminal that is grounded (connected to the chassis). The negative terminal is normally the grounded post.

3

. Charging a negatively grounded battery. Connect the red cable to the positive terminal on the battery and the black cable to 

good metal engine ground away from the battery. Ensure you do not connect the black cable to fuel lines or sheet-metal body 
parts. 

4

. Charging a positively grounded battery. Connect the black cable to the negative terminal on the battery and the red cable to 

good metal engine ground away from the battery. Ensure you do not connect the black cable to fuel lines or sheet-metal body 
parts. 

Connecting the charger to an out of vehicle battery:

1

. The power cord should be disconnected when connecting or disconnecting the battery leads.

2

. Connect the red cable to the positive terminal on the battery and the black cable to the negative terminal. 

If the battery leads have been connected incorrectly, the reverse polarity protection system will ensure that neither the charger 
nor the battery are damaged. 

Start charging

1

. Connect the charger´s AC cord to an AC Power Supply. The charger will indicate POWER, yellow indication lamp (B).

2

. The lamp for completely discharged battery (1) will illuminate if the battery’s voltage is less than 12V. 

3

. Normal charging will be indicated by the following lights: completely discharged battery (1), bulk charging (2), absorption 

charging (3) or maintenance charging (4). When the maintenance charging lamp illuminates the battery is fully charged. 
Charging will start if the voltage drops. The charger can normally be connected for months. Reconditioning is indicated by the 
lamp (5) illuminating. 

4

. If the battery leads have been connected incorrectly, the reverse polarity protection system will ensure that neither the 

charger nor the battery are damaged. 

5

. If nothing happens. If the lamp indicating the setting and the power lamp remain lit but no other lamp illuminates, the 

connection to the battery or chassis may be poor or the battery may be faulty. Another cause may be a lack of voltage in the 
AC Power Supply. Begin by improving the connection between the battery and charger.

6

. Charging can be stopped at any time by disconnecting the charger’s AC cord. Always disconnect the AC cord before 

disconnecting the battery leads. When you stop charging a battery installed in a vehicle you should always disconnect the 
battery lead from the chassis before disconnecting the other battery lead.

Summary of Contents for M200

Page 1: ...M200 Battery Charger For lead acid batteries User Manual and Guide to professional charging of starter and deep cycle batteries EN ...

Page 2: ...e must be replaced by a CTEK representative using an original part supplied by CTEK A detachable cable can be replaced by the user using an original part supplied by CTEK Connection to the mains supply must be in accordance with the national regulations for electrical installations Chargers with grounded mains plug must only be connected to a grounded socket outlet During charging Lead Acid batter...

Page 3: ...onnecting or disconnecting the battery leads 2 Connect the red cable to the positive terminal on the battery and the black cable to the negative terminal If the battery leads have been connected incorrectly the reverse polarity protection system will ensure that neither the charger nor the battery are damaged Start charging 1 Connect the charger s AC cord to an AC Power Supply The charger will ind...

Page 4: ...art Lamp 1 Start mode for the charging cycle The start phase continues until the battery s terminal voltage has risen above the set limit at which point the charger switches to bulk charging If the terminal voltage has not passed the voltage limit within the time limit the charger switches to fault mode lamp 0 and discontinues the charging If so the battery is faulty or its capacity is too large B...

Page 5: ...icated by a lit temperature sensor indicator lamp The charging voltage is then adjusted to the 25 C condition SPECIFICATION Model 1055 Voltage AC 220 240VAC 50 60Hz Charging voltage 14 4V Charging current 15A max Current mains 2 9A rms at full charging current Back Current Drain 2Ah per month Current ripple 4 Ambient temperature 20 C 50 C Output power is automatically reduced at higher temperature...

Page 6: ...minimal fluid loss M200 PARAMETERS Mode Desulphation Soft Start Bulk Absorption NORMAL or RECOND YES Max 4h or until the voltage reaches 12 6V 15A for max 20h NIGHT Mode max 5A 14 4V until 4h after the current dropped to 4 5A max 16h Note In NIGHT Mode the M200 operates in NORMAL Mode with reduced current and disabled fan The unit automatically returns to NORMAL after 8h ...

Page 7: ...ce for maximum performance Maintenance for maximum battery life Analysis Recond Float Pulse Warning indication if voltage drops to 12 0V in 3 minutes Max 15 8V and 3A for 4h for deeply discharged batteries Otherwise for 30 minutes only in Recond mode 13 6V with max 15A for max 10 days Pulse start at 12 9V max voltage 14 4V ...

Page 8: ... transportation cost prepaid This warranty is void if the unit is abused handled carelessly or repaired by anyone other than CTEK SWEDEN AB or its authorized representative CTEK SWEDEN AB makes no warranty other than this limited warranty and expressly excludes any implied warranty including any warranty for consequential damages This is the only expressed limited warranty and CTEK SWEDEN AB neith...