Installation manual CHARGESTORM® Connected

 

 

1

 

 

Introduction 

This document shows how to install and use the charge station CHARGESTORM® Connected.  

 

Figure 1 CHARGESTORM® Connected  

 

1)

 

Front panel 

2)

 

Display with charging status symbols 

3)

 

Back cover 

4)

 

Technical box  

5)

 

EV connector (outlet or cable) 

The manual is valid for the CHARGESTORM® Connected family. Model information is found on the 

top of the technical box. For a complete list of article numbers, please download datasheet at 

www.ctekemobility.com. 

2

 

Safety 

 

Only accredited electrician is allowed to perform the installation described in this document 

 

Read and follow the instructions in this document before installation and usage of the product 

 

Installation must fulfill local safety regulations 

3

 

Delivery content 

Part of delivery 

 

Charging station 

 

Installation and user manual  

 

Two keys for opening CHARGESTORM® Connected 

 

Cover for cable inlet (M32 and M12). 

 

Holder for charging gun (In case charging station is equipped with fixed cable) 

 

To bring 

 

4 pcs screws (M8) for wall mounting. Select screw type depending of wall.  

 

4 pcs of rubber seal/gaskets to use with screw. 

 Note very important! 

 

RFID-tag (in case RFID shall be used) of type Mifare Classic/ IEC 14443 Type A. RFID-tags can 

be ordered from CTEK E-Mobility web-shop (

www.ctekemobility.com).

 

 

Option 

 

CHARGESTORM® Connected pole mount kit for pole diameter 60 mm. Article number 920-

00010. 

Summary of Contents for E-MOBILITY CHARGESTORM Connected

Page 1: ...document Read and follow the instructions in this document before installation and usage of the product Installation must fulfill local safety regulations 3 Delivery content Part of delivery Charging...

Page 2: ...available for use inside CHARGESTORM Connected Make sure that power is off during installation 4 3 Network connection In case CHARGESTORM Connected shall be connected to a portal or a local controlle...

Page 3: ...ing CHARGESTORM Connected in direct light sunlight Symbol visibility is limited and heat in the unit is increasing CHARGESTORM Connected has a temperature sensor in the unit that adjust charging curre...

Page 4: ...le gland for 1 that is delivered with the product supports cable dimensions between12 22mm while the gland for 2 supports 3 6mm The glands must be replaced if the cables are outside specified range If...

Page 5: ...e end The wires cross section area must not exceed 16mm2 Make sure protected ground wire is longer than the other wires sot that it will be the last wire to detach if pulled Connect the supply wires t...

Page 6: ...nect cable to RJ45 connector on the control board located on the front panel When cable is connected in both ends shall link and activity led on the RJ45 connector be active If 3G is in use check that...

Page 7: ...dard USB port is used on the computer for configuration If the computer is running Microsoft Windows must an Ethernet to USB driver be installed to support access to the local web interface For Linux...

Page 8: ...r Configuration interfaces When network configuration is ready check on the status page that internet access is established Ethernet To set the IP settings for Ethernet follow the instruction below Un...

Page 9: ...WWAN is a specific 3G mode WWAN tends to be more robust than PPP described in previous chapter Follow the step by step instruction to configure WWAN Under Configuration Interface General select WAN W...

Page 10: ...owing format wss companyname oamportal com Ocpp websocket Chargeboxid must not contain more than 22 characters and it must be unique charging stations cannot have the same chargeboxid CHARGESTORM Conn...

Page 11: ...D tags that shall be activated on CHARGESTORM Connected 7 Product information Power input Power 16 32A 230V 1 phase or 16 32A 400V 3 phase 50Hz Power input connector depends on model Charging current...

Page 12: ...intenance of CHARGESTORM Connected shall be conducted at least once per year At installation and maintenance of CHARGESTORM Connected shall the following tests be performed Test Trip ground circuit br...

Page 13: ...Installation manual CHARGESTORM Connected page 13 11 Electrical schematics 11 13 phase Below is an example of a schematics for CHARGESTORM Connected 3ph dual outlet...

Page 14: ...Installation manual CHARGESTORM Connected page 14 11 1 IT nett Below is an example of a schematics for CHARGESTORM Connected 1ph dual outlet IT nett...

Page 15: ...orrect in the manual CTEK E Mobility is not responsible for faults or incidents or damages that can be traced to the usage of this manual Copyright CTEK E Mobility All rights restricted copying adapti...