background image

4 •  

FUNCTIONS

•   General 

D250T is a 24V DC-DC battery charger for a dual battery system with a starter battery and 

a service battery. D250T is designed to be used as an onboard charger, for charging and 

maintaining a 24-volt service battery from the vehicle alternator when motor is running.

•   Charging 

D250T uses a 4-step automatic charging algorithm to charge the service battery with up to 10A 

when a conventional alternator (constant voltage) is running.

•  Starter battery under voltage protection 

The charging process is automatically switched off when the engine is not running to prevent 

discharge of the starter battery.

•  Temperature compensation 

The external temperature sensor will adjust the charge voltage according to actual temperature 

of the service battery. The charge voltage is reduced at higher temperatures and is increased at 

lower temperatures. The temperature sensor should if possible be attached to the Service Battery, 

or as close to it as possible. (see figure 4)

•  Battery separation 

D250T separates the starter battery from the service battery when the engine is not running. The 

battery separation protects the starter battery from being discharged, this eliminates the needs for 

diodes and VSR relays.

•  Service battery temperature protection 

The external temperature sensor attached to the service battery is protecting the service battery 

from high temperatures by switching off the charging process if the measured temperature rises 

too high. The charger will automatically restart when the service battery temperature reduces to a 

level level within the specified operating temperature.

•  Equalizing the starter battery 

In a 24V system, where we have two 12V batteries in series, the voltage in the two batteries can 

be unbalanced, especially if there are 12V consumers connected to one of the batteries. When 

the service battery is fully charged, the D250T will measure the voltage levels in both 12V starter 

batteries. If there is a difference between the voltage in these two batteries, the D250T is will 

equalize the voltage levels to increase battery performance and lifetime.

•  Protects service battery from overcharging 

D250T will not overcharge the service battery. When the service battery is fully charged D250T 

will go into pulse charging mode to monitor and maintain the charge status battery. If battery 

voltage drops too low the charging process will restart.

•  SMARTPASS 120T 

Fully compatible with SMARTPASS 120T to provide the ultimate power management solution for 

dual battery systems.

•  Remote status indicator lamp 

There are no LED indicator lamps on the units themselves but there is a status signal lead attached 

to the charger. This can be connected to a 24V lamp (Max. 2W) for remote indication of charger 

status, in the driver’s cab or other places where indication is needed.

D250T

D250T

Summary of Contents for D250T

Page 1: ...USER MANUAL CTEK DC DC BATTERY CHARGER D250T AND 24V POWER MANAGEMENT SYSTEM SMARTPASS 120T 2 YEAR WARRANTY EN DE FR ES IT NL SV DA NO FI PL JA KO ZH...

Page 2: ...o ensure that the unit will not be overheated Never place the charger above the battery and do not cover the charger during charging Disconnect the battery terminal posts before installing The D250T a...

Page 3: ...vice battery is protecting the service battery from high temperatures by switching off the charging process if the measured temperature rises too high The charger will automatically restart when the s...

Page 4: ...overcurrent protection SMARTPASS 120T can handle temporary inputs and outputs of up to 350A for fast charging It has an overcurrent protection and internal temperature monitoring to protect electroni...

Page 5: ...5 m 15 ft 10 m 30 ft D250T IN IN 2 5 mm2 AWG14 2 5 mm2 AWG14 4 mm2 AWG12 4 mm2 AWG12 6 mm2 AWG10 15A OUT OUT 2 5 mm2 AWG14 4 mm2 AWG12 6 mm2 AWG10 15A EQU 2 5 mm2 AWG12 2 5 mm2 AWG12 4 mm2 AWG12 4 mm...

Page 6: ...ure 5 5 Use tape see Figure 4 to secure the temperature sensor to a clean flat surface above the service battery Position the sensor as close to the positive terminal post as possible 6 Connect the ba...

Page 7: ...nches 4 9 mm 0 19 inches 168mm 6 inches Figure 3 Ignition signal 15 clamp DIN 72552 Temperature sensor Smart alternator cable red Chassis Earth SETTINGS SMARTPASS 120T Smart alternator cable red Type...

Page 8: ...rature This can be done by attaching the temperature sensor to the starter battery or somewhere close to the battery BATTERY TEMPERATURE PROTECTION Protects the battery by switching off charging if th...

Page 9: ...rvice battery that require power when the vehicle is running One basic condition required for this installation is that the alternator can deliver sufficient voltage to supply equipment and split char...

Page 10: ...is not enough to fully charge the service battery Additional charge is needed to fill the battery up to 100 Maintenance charging of the service battery and starter battery during long time storage of...

Page 11: ...an one errors For further details please refer to the manual see FUNCTION INDICATIONS table SMARTPASS 120 OUT OUT IN Reason Internal temperature too high and or current too high in connection between...

Page 12: ...ing 25 5V for 4 sec engine running alternator not charging Smart alternator cut in Not applicable 23 6V for 4 sec engine running alternator charging Smart alternator cut out Not applicable 22 8V for 4...

Page 13: ...ly or repaired by anyone other than CTEK or its authorised representatives One of the screw holes in the bottom of the product may be sealed Removing or damaging the seal will void the warranty CTEK m...