CTC Union FRM220-CH08 Hardware Installation Download Page 14

Chapter 3  Management Quick Start 

14 

 

Chapter 3. Management Quick Start 

3.1 Introduction 

The information here is only a brief introduction to the management interfaces and methodologies for managing 

the FRM220. For in-depth use of the management features of the FRM220, please refer to the 

FRM220 NMC User 

Manual

3.2 Management Methods 

The  management  methods  for  the  FRM220  include  textual  based  serial  console,  IP  based  textual  console 

(Telnet), web based GUI management through web browser, SNMP management through proprietary MIB and via 
CTC Union's Element Management System (EMS). 

3.3 Console Terminal 

The NMC card has a DB9F RS-232 serial console port for local management purposes. The console provides 

a menu driven display, with simple keyboard item selections and the ability to control all aspects of management in 
the FRM220. The console interface also provides the initial provisioning to setup the TCP/IP interface (the Ethernet 
RJ-45 10/100Base-TX port) for remote management by Telnet, Web, SNMP and EMS. 

3.3.1 Terminal Connection & Settings 

The DB9F port on the NMC is a DCE (Data Communications Equipment) wired device that allows for direct 1:1 

cable connection to the DTE (Data Terminal Equipment) of PC's COM port. The FRM220 includes the 1:1 DB9F to 
DB9M  serial  cable  for  connection  to  PC's  COM  port  or  laptop's  USB  to  RS-232  adapter.  Any  VT100  terminal 
emulation program 

for Windows may be used, including HyperTerminal™, TeraTerm, or PuTTY. 

 

The terminal settings must follow these communication parameters: 

115200 data rate 
8 bits 
No parity bit 
1 Stop bit 
No Flow Control 

3.3.2 Terminal Login 

Connect the console cable to PC  and power  up the FRM220. Start  your favorite terminal  emulation program. 

The terminal screen is refreshed every few seconds. By default, no password is set from the factory, so you should 
immediately see a screen like that below. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Items of interest: 

1. This is the display header. The version shown reflects the currently installed 'romfs.gz' or file system version (5.27). 
2. This block supports selecting any of the installed cards, numbered in slots 1~8. 
3. In this block of commands is the all important 'SNMP System Configuration Setup'. The TCP/IP settings are done through 
this selected menu. 

               **************************************** 
               *** CTC UNION TECHNOLOGIES CO., LTD. *** 
               *** FRM220 NMC             VER. 5.27 *** 
               **************************************** 
 
 
 
<1>:SLOT #01 > NMC & Chassis 
<2>:SLOT #02 > FRM220-16G-3R 
<3>:SLOT #03 > Empty 
<4>:SLOT #04 > FRM220-10G-SS 
<5>:SLOT #05 > FRM220-FOM01 
<6>:SLOT #06 > FRM220-1000MS 
<7>:SLOT #07 > FRM220A-Eoe1 
<8>:SLOT #08 > FRM220-DS3/E3 
 
 
 
<L>:SNMP System Configuration Setup 
<M>:SNMP Manager Configuration Setup 
<P>:Password Setup 
<R>:Reboot           <Z>:Logout 
Please select an item. 

Summary of Contents for FRM220-CH08

Page 1: ...FRM220 CH08 Hardware Installation...

Page 2: ......

Page 3: ...x 886 2 27991355 Email sales ctcu com URL https www ctcu com FRM220 CH08 Hardware Installation Manual Fiber In band Managed Media Platform Rack 8 Slot 1U Version 1 0 February 7 2012 official release V...

Page 4: ...injury or death that may be associated with such unintended or unauthorized use even if such claim alleges that CTC Union Technologies was negligent regarding the design or manufacture of said product...

Page 5: ...3 Mechanical Assembly 10 2 3 1 Rack mounting 10 2 3 2 Power Fan Modules Removal Replacement 11 2 3 3 Line Card Conversion Stand alone Rack 11 2 4 Electrical Installation 12 2 5 Alarm Installation 12...

Page 6: ...Table of Contents ii...

Page 7: ...dular Media Chassis provides an economic solution for high density Fiber Converter installations in enterprises or central offices All critical components Power fans management module and interface ca...

Page 8: ...1 ON relay 1 is closed ALM 2 Red When On NMC has set Alarm 2 ON relay 2 is closed Figure 1 2 Relays and LEDs 1 4 Chassis Rear Description The rear panel holds the hot swappable power fan modules The...

Page 9: ...CC part 15 subpart B class A Reliability MTTB 65 000 hours 25 C Physical Specifications Dimensions 438mm Width x 302mm Depth x 44mm Height US 17 1 4 wide x 11 7 8 deep x 1 3 4 high Weight 2 6Kg US 5 7...

Page 10: ...t on 2 2 Site Preparation Install the FRM220 CH08 within reach of an easily accessible grounded AC outlet or three wire 48VDC Power return Earth Ground central office power The AC outlet should be cap...

Page 11: ...the 2 7G and 10G the chassis will require two power fan modules or overheating could result Figure 2 2 Power Modules for CH08 2 3 3 Line Card Conversion Stand alone Rack The FRM220 Media Converter Li...

Page 12: ...the power cable in AC installations or via the frame ground connection for DC installations Figure 2 4 IEC AC terminal block DC power connector pin assignment 2 5 Alarm Installation The alarm relay p...

Page 13: ...ings slot number 1 may then be used for a non managed media converter line card 2 7 Line Card Installation The Line Cards for the FRM220 Series are Fiber Media Converter Cards which slide into CH08 ch...

Page 14: ...inal Equipment of PC s COM port The FRM220 includes the 1 1 DB9F to DB9M serial cable for connection to PC s COM port or laptop s USB to RS 232 adapter Any VT100 terminal emulation program for Windows...

Page 15: ...upgrade line cards in the FRM220 Setup the default gateway subnet mask and IP address as instructed by your network administrator After any TCP IP setting change the NMC must be rebooted So ESC back...

Page 16: ...ement IP address The following is an example of a Telnet screen It is the same as a local serial console screen only it can be accessed remotely 3 5 Web Based Manager The FRM220 NMC supports web based...

Page 17: ...d by CTC Union It is a client server architecture using a Windows based server with Microsoft MS SQL Server for a database and Java based server and client The client software can be run on the server...

Page 18: ...Chapter 3 Management Quick Start 18...

Page 19: ......

Page 20: ......

Reviews: