15
CTC EcoPart 400
General information
1
3
2
4
5
8
6
7
9
10
11
12
13
15
14
16
17
1. Brine (heat source)
2. Water
3. Evaporator
4. Condenser
5. Compressor
6. Expansion valve (electronic)
7. Drying filter
8. Refrigerant exchanger
9. Low pressure sensor
10. High pressure sensor
11. High pressure switch
12. T suction gas
13. T discharge
14. T brine
15. T water out
16. T water in
17. Control expansion valve
2.5 Refrigerant system
2.6 Operating range
The operating range for the heat pump is defined by the conditions in the test
standard EN 14511, and are given by source and supply temperatures. In reality,
CTC EcoPart is monitoring the operating range by continuous pressure sensors.
In many cases CTC EcoPart can reach higher supply temperatures than stated
by the operating range.
Operating range (source/supply °C) according to the test standard EN 14511:
-5/25
-5/61
+20/25
+20/59