background image

 

MNX10014 / Rev C 

 

 

1/11/2010 

 

 
 
 

Class 1 Div 1 (Zone 0) Labeling  

(AC90*/LP80*/LP90*) 

 

INTRINSICALLY SAFE 

SECURITE INTRINSEQUE  

Ex ia IIC T3 / T4 

Ex iaD A20 T150

o

C (T-Code = T3) / T105

o

C (T-Code = T4)  

DIP A20 IP6X T150

o

C (T-Code = T3) / T105

o

C (T-Code = T4)  

AEx ia IIC T3 / T4  

AEx iaD 20 T150

o

C (T-Code = T3) / T105

o

C (T-Code = T4) 

CLI GPS A,B,C,D 

CLII, GPS E,F,G, CLIII 

CLI, ZONE 0, ZONE 20 

OPERATING TEMP CODE: T3 

AMBIENT TEMP RANGE = -54

o

C TO +125

o

OPERATING TEMP CODE: T4 

AMBIENT TEMP RANGE = -40

o

C TO +80

o

CONTROL DRAWING INS10012 

Ex ia IIC T3 -54

o

C < Ta < +125

 o

Ex ia IIC T4 -40

o

C < Ta < +80

o

Ui=28VDC    Ii=100mA  

Ci=70nF    Li=51uH    Pi=1W 

CSA 221421 

KEMA 04ATEX1066 

 

AC90* Series – Temperature Code: T3 

Ambient Temperature range = -54

o

C to +125

o

 

LP80*, and LP90* Series – Temperature Code: T4 

Ambient temperature range = - 40

o

C to +80

o

 

Figure 2. Specific Nameplate Markings for ATEX/CSA Intrinsic Safe Parameters 

 
 
 
 
 
 
 
 
 
 
 
 

Figure 1. Nameplate Marking 