P1 PC/104 Cover Installation
CTC Parker Automation
5
7. Secure the PC/104 cover to the backshell using four metric 3x5
(M3x5) screws provided with the PC/104 expansion cover kit.
8. Perform any cable connections or further setup required for the
PC/104 card.
The P1 PowerStation with the expansion cover is now ready to be mounted
back in its enclosure.
Note
Access to the Compact Flash (CF) card on the PowerStation is
restricted once the PC/104 expansion cover is installed on the
P1 unit. If you wish to remove or replace the CF card on the
PowerStation, the PC/104 cover may need to be removed.
Installing the PC/104 Cover for Three Cards
Installation of a PC/104 Expansion Cover for three cards is similar to the
installation of the cover for two cards, except for a few additional steps.
Follow these steps to install the expansion cover for three cards:
1. Follow Steps 1 through 6 for installing a PC/104 expansion cover
for one card. See the first set of instructions at the beginning of this
document.
2. Follow Steps 2 through 4 for installing a PC/104 expansion cover
for two cards. See the preceding set of instructions.
Refer to the preceding two card installation diagram for a
visual representation of the following installation steps.
3. Install the third PC/104 card securely onto the second PC/104 card
connector.
The third PC/104 card should rest evenly on the longer set of
standoffs.
Note
If you are installing a PC/104 card on top of a MachineLogic
Control Adapter, be sure that no metallic parts of the card are
touching the touch relay of the Control Adapter (metallic box on
bottom of the card). Otherwise, a short may occur and damage
the MachineLogic Control Adapter.
If you are installing a PC/104 MachineLogic Control Adapter
with a UCS adapter, it must be installed last (top card) in order