CSS CONTINENTAL iTouch Rasul GS08M2 User Manual Download Page 3

The Rasul program runs for 30 minutes. Once the Rasul program starts, a countdown

time is displayed on the interface as shown in picture 1 from 30minutes to 0 minutes.

Touch the  “          “ button to start the Rasul program. The steam generator will

immediately fill with water and begin to heat. At this time the normal lights are on 

and will stay of for the first 5 minutes.

There after the normal lights will turn of and the steam will continue to for 25minutes. 

At 25 minutes steam production will stop and the overhead sprayers will spray water 

for 5 minutes and then stop.

At this time the normal lights will switch on, indicating the end of the session. 

The normal lights will remain on until the on/of button is pressed.

GS08M2 USER MANUAL

GS08M2 USER MANUAL

The RASUL Session Explained

Switching from Celsius to Fahrenheit

Enter the interface as shown in picture 6 by pressing the  “          “ button.

Now select the  “         “ column and press the  “      “ button to enter the interface as 

shown in picture 5. 

Now press the  “          “ button to change from Celsius to Fahrenheit.  

OK

OK

Restore Factory Settings

OK

OK

Enter the interface as shown in picture 6 by pressing the  “          “ button.

Now select the  “                     “ column and press the  “        “ button to enter the interface. 

Now press the  “          “ button to restore factory settings.  

Real Clock

Enter the interface as shown in picture 6 by pressing the  “          “ button.

Now select the  “                     “ column and press the  “        “ button to enter the interface 

as shown in picture 7. 

Now press the  “         and       “ button to the data you would like to set, such as hour, 

minute, date, month and year.

Press the         and          buttons to adjust the data. Press“        “ to save your settings 

and press “ Exit “  to exit settings.

OK

OK

Trouble Shooting

Error Code information

Technical Parameters

Please check the water supply, and if there 

are any obstructions in the inlet valve.

Please check if the tank is burning dry.

Please check the sensor cable connections. 

If there are no problems, replace sensor.

Please check the sensor cable connections. 

If there are no problems, replace sensor.
Please check the sensor cable connections. 

If there are no problems, replace sensor.

       High-Limit

Water Inlet Problem

External Temp Sensor 

        Short Circuit

        Temp Sensor 

        Open Circuit
        Temp Sensor 

        Short Circuit

Error Code

Possible Cause

Trouble-shooting Method 

03

05

07

08

09

Steam starts and 

normal light works 

for 5 minutes

normal light off and 

steam continues for 

20 minutes

Steam off and 

Sprayers work for 

5 minutes

Normal light 

switches on after  

30 minutes

Rasul program duration is 30 minutes