HV Breakout Module – Mounting and installation
Installation Manual
19
Version 01.20 // 2021
"
Fig. 4-14: HV BM 1.2, remove the nuts from the threaded bolts on either side
Loosen the nuts on either side of the shunt module and remove them
from the threaded bolts.
"
Fig. 4-15: HV BM 1.2, remove the shunt module from the threaded bolts
Remove the shunt module from the threaded bolts. Make sure that the
shunt cables will not be damaged.
Fig. 4-16: HV BM 1.2, remove the spacers from the threaded bolts
"
Remove the spacers from the threaded bolts.
"
Fig. 4-17: HV BM 1.2, place the shunt module and the ring terminals on the threaded bolts
Put the shunt module back on the threaded bolts.
"
Place the ring terminals upside down on the threaded bolts. Make sure that the
surface of the ring terminal rests plane on the mounting surface (shunt module).
"
Fig. 4-18: HV BM 1.2, fasten the ring terminal with the nuts
Fasten the ring terminal with the nuts. Observe the tightening torque!
→ See Tab. 4-2: Tightening torques for the mounting of ring terminals.