MR-AHU Installation Sheet

 

Installation Sheet (TCON154 11/97)

1

 

Controller Installation

 

1.

 

Check the mounting location for the MR-AHU. The 
available area must measure at least 4.3" 

 

×

 

 8" (11.0 

 

×

 

 20.3 

cm) and should be in a moisture free container away from 
anylarge electrical devices. The screw holes are 3.75" 

 

× 

 

7.5" 

(9.5 

 

×

 

 19.1 cm) as shown in 

Figure1, “MR-AHU 

(Covered)”

, and will require phillips or slotted pan head 

screws.

 

2.

 

You will not need to remove the plastic cover to install the 
MR-AHU, or any of the connections. To replace the 4A FB 
fuse, remove the plastic cover, remove the old fuse and 
install a new fuse (see 

Figure2, “MR-AHU (Cover 

Removed)”

).

 

Connecting the Input Devices

 

Warning:

 

Ensure that no power is connected to the MR-AHU 
during electrical installation. Failure to disconnect 
power from all interconnected equipment when 
performing electrical installation may result in damage 
to the components and/or electrical shock or burns

 

1.

 

Connect the external input devices (contact or thermistor) 
leads to an input terminal, TB4 – 1 through TB4 – 4 (Input 
1 to Input 4, see 

Figure3, “Input Device Connections”

).

 

2.

 

Connect the other input device lead (common return lead) 
to the signal ground terminal, TB4 – 6 (Ground).

 

 

Figure 1.

MR-AHU (Covered)

Figure 2.

MR-AHU (Cover Removed)

GROUND

OUTPUT 6

OUTPUT 5

OUTPUT 4

OUTPUT 2

OUTPUT 3

OUTPUT 1

TRIAC OUTPUTS

24VAC. 0.5A EACH. 2.0A TOTAL

1

2

3

4

5

6

TB4
INPUTS

GROUND

+12V

INPUT 4

INPUT 3

INPUT 2

INPUT 1

INPUT PORT

TEST

D1

U1

TB5
OUTPUTS

S1

1

2

3

4

5

6

7

SENSOR

LAN

P1

TB1

TB2

AC PWR

TB3

12

1

2

3

12

LAN +

LAN –

24V ~

GROUND

SIGNAL

POWER

GROUND

PWR

LAN

PORT

I/STAT

PORT

ADDRESS-01
ADDRESS-02
ADDRESS-03
ADDRESS-04
ADDRESS-05
FUNCTION-06
FUNCTION-07
FUNCTION-08
FUNCTION-09
FUNCTION-10
FUNCTION-11
FUNCTION-12

SWITCHES

OUTPUT 1

TEST

OUTPUT 2
OUTPUT 3
OUTPUT 4

OUTPUT 6

OUTPUT 5

TRANSMIT

RECEIVE

STATUS DISPLAY

Micro-Regulator

UL

LISTED

ENERGY MANAGEMENT
EQUIPMENT
POWERED BY A SINGLE
CLASS 2 SOURCE

MODEL:

SERIAL NO.:

POWER:

24V – 7VA

(55VA MAX)

MADE IN USA

BY:

CONTROL SYSTEMS

INTERNATIONAL

P.O. BOX 59469

DALLAS, TX

75229

MR-AHU

 8.00 " 

 7.50 " 

 4.30 " 

 3.75 " 

DIN Rail
Mounting
Clips

Test

D1

1
2
3
4
5
6
7
8

TX

RX

U1

TB5
OUTPUTS

S1

1

2

3

4

5

6

7

1

2

3

4

5

6

TB4
INPUTS

330815–

SENSOR

LAN

P1

TB1

TB2

AC PWR

FS1

TB3

12

12

1

2

3

COPYRIGHT 1995 CSI, INC

MADE IN USA

Inputs

24 VAC Power Input

Sub-LAN Port

I/STAT Port

Address/Function
Select Dip Switches

LED Communications
Indicators

Control Outputs

4 A FB
Replaceable Fuse

 

Figure 3.

Input Device Connections

1

2

3

4

5

6

TB4
INPUTS

10K ohm Thermistor

GROUND

+12V

INPUT 4

INPUT 3

INPUT 2

INPUT 1

INPUT PORT

1

2

3

4

5

6

TB4
INPUTS

10K ohm Thermistor

GROUND

+12V

INPUT 4

INPUT 3

INPUT 2

INPUT 1

INPUT PORT

Mixed Air

Temperature

Sensor

S/P/L Contact

MR-AHU with Binary Load
AHU_2100 and Earlier:

MR-AHU with Binary Load
AHU_2200 and Later: