![CSI alfa laval Unique RV-P Instruction Manual Download Page 16](http://html.mh-extra.com/html/csi/alfa-laval-unique-rv-p/alfa-laval-unique-rv-p_instruction-manual_2692612016.webp)
ALFA LAVAL UNIQUE RV-P VALVE INSTRUCTION MANUAL—REV 6/20
4 Operation
Pay attention to possible faults. Study the instructions carefully.
The items refer to the parts list and service kits section.
4.2 Troubleshooting
N
NO
OTTE
E!!
Study the maintenance instructions carefully before replacing worn parts - section 5.1 General maintenance.
P
Prroobblleem
m
C
Caauussee//rreessuulltt
R
Reeppaaiirr
External product leakage
Worn or damaged lip
seal and/or O-ring
- Replace the seals
- Replace with seals of a
different rubber grade
Internal product leakage
- Worn or product-affected
plug seal
- Replace the seal
- Replace with a seal of a
different rubber grade
- Product deposits on
the seat and/or plug
- Frequent cleaning
Water hammer
The flow direction is the
same as the closing direction
- The flow direction should be
against the closing direction
- Throttle air release of solenoid in
top unit
4.3 Recommended cleaning
S
Stteepp 11
A
Allw
waayyss handle lye and acid with great care.
C
Caauussttiicc ddaannggeerr!!
A
Allw
waayyss use
rubber gloves!
A
Allw
waayyss use
protective goggles!
S
Stteepp 22
!
N
Neevveerr touch the valve or the pipelines when sterilising.
D
Daannggeerr ooff bbuurrnnss!!
2405-0011
!
16
CONTACT CSI FOR MORE INFORMATION | CSIDESIGNS.COM | [email protected] | 417.831.1411